SUPERSERVER 6015B-T+/6015B-8+ User’s Manual

JLAN Enable/Disable

Change the setting of jumper JPL1 and JPL2 to enable or disable the on- board LAN ports JLAN1 and JLAN2, respectively. See the table on the right for jumper settings. The default setting is enabled

Watch Dog Enable/Disable

JWD controls the Watch Dog function. Watch Dog is a system monitor that can reboot the system when a software application hangs. Pins 1-2 will cause WD to reset the system if an application hangs. Pins 2-3 will generate a non- maskable interrupt signal for the appli- cation that is hung up. See the table on the right for jumper settings. Watch Dog must also be enabled in BIOS.

Note: When enabled, the user needs to write their own application software to disable the Watch Dog Timer.

3rd Power Supply Fail Detect Enable/Disable

The system can notify you in the event of a power supply failure. This feature assumes that three power supply units are installed in the chassis with one acting as a backup. If you only have one or two power supply units installed, you should disable this (the default set- ting) with J3P to prevent false alarms. See the table on the right for jumper settings.

JLAN Enable/Disable

Jumper Settings (JPL1/JPL2)

Jumper Setting

Defi nition

Pins 1-2

Enabled

Pins 2-3

Disabled

 

 

Watch Dog

Jumper Settings (JWD)

Jumper Setting

Defi nition

Pins 1-2

Reset

Pins 2-3

NMI

Open

Disabled

 

 

3rd Power Supply Fail Detect Enable/Disable Jumper Settings (J3P)

Jumper Setting

Defi nition

Open

Disabled

Closed

Enabled

 

 

5-20