SUPERSERVER
JLAN Enable/Disable
Change the setting of jumper JPL1 and JPL2 to enable or disable the on- board LAN ports JLAN1 and JLAN2, respectively. See the table on the right for jumper settings. The default setting is enabled
Watch Dog Enable/Disable
JWD controls the Watch Dog function. Watch Dog is a system monitor that can reboot the system when a software application hangs. Pins
Note: When enabled, the user needs to write their own application software to disable the Watch Dog Timer.
3rd Power Supply Fail Detect Enable/Disable
The system can notify you in the event of a power supply failure. This feature assumes that three power supply units are installed in the chassis with one acting as a backup. If you only have one or two power supply units installed, you should disable this (the default set- ting) with J3P to prevent false alarms. See the table on the right for jumper settings.
JLAN Enable/Disable
Jumper Settings (JPL1/JPL2)
Jumper Setting | Defi nition | |
Pins | Enabled | |
Pins | Disabled | |
|
|
Watch Dog
Jumper Settings (JWD)
Jumper Setting | Defi nition | |
Pins | Reset | |
Pins | NMI | |
Open | Disabled | |
|
|
3rd Power Supply Fail Detect Enable/Disable Jumper Settings (J3P)
Jumper Setting | Defi nition | |
Open | Disabled | |
Closed | Enabled | |
|
|