SUPER MICRO Computer 6015B-8+ OS Boot Watch Dog, Timer for Loading OS Minutes, Time Out Option

Models: 6015B-8+

1 124
Download 124 pages 50.99 Kb
Page 94
Image 94
OS Boot Watch Dog

SUPERSERVER 6015B-T+/6015B-8+ Manual

OS Boot Watch Dog

Set to Enabled to enable OS Boot Watch Dog. The options are Enabled and Disabled.

Timer for Loading OS (Minutes)

This feature allows the user to set the time value (in minutes) for the previous item: OS Boot Watch Dog by keying-in a desired number in the blank. The default setting is 10 (minutes.) (Please ignore this option when OS Boot Watch Dog is set to "Disabled".)

Time Out Option

This feature allows the user to determine what action to take in an event of a system boot failure. The options are No Action, Reset, Power Off and Power Cycles.

System Event Log/System Event Log (List Mode)

These options display the System Event (SEL) Log and System Event (SEL) Log in List Mode. Items include: SEL (System Event Log) Entry Number, SEL Record ID, SEL Record Type, Time Stamp, Generator ID, SEL Message Revision, Sensor Type, Sensor Number, SEL Event Type, Event Description, and SEL Event Data.

7-22

Page 94
Image 94
SUPER MICRO Computer 6015B-8+ manual OS Boot Watch Dog, Timer for Loading OS Minutes, Time Out Option