Configuring VCS clusters for data integrity 103

Setting up disk-based I/O fencing manually

To verify I/O fencing configuration

On one of the nodes, type:

# vxfenadm -d

I/O Fencing Cluster Information:

================================

Fencing Protocol Version: 201

Fencing Mode: SCSI3

Fencing SCSI3 Disk Policy: dmp

Cluster Members:

*0 (galaxy)

1 (nebula)

RFSM State Information:

node 0 in state 8 (running) node 1 in state 8 (running)

Removing permissions for communication

Make sure you completed the installation of VCS and the verification of disk support for I/O fencing. If you used rsh, remove the temporary rsh access permissions that you set for the nodes and restore the connections to the public network.

If the nodes use ssh for secure communications, and you temporarily removed the connections to the public network, restore the connections.

Page 103
Image 103
Symantec 5 manual Removing permissions for communication, # vxfenadm -d