4 - Menu interface, etc.
23
TASC AM D A-78H R

the current position of the knob and the cur-

rent parameter value do not match.

3When the SHUTTLE/DATA indicator kno b

blinks rapidly, the current position of the knob

matches the current parameter value. Turning

the knob from this position will now allow the

parameter value to be changed.

4Turn off th e “data e ntry” m od e using the

SHIFT and SHUTTLE/DATA key com b in ation.

Until the match described above has been made, the

value of the parameter cannot be changed using the

knob.

Note that because of the precision of the knob, the

value may sometimes appear to “jump”.

Fine- tu ning of val ues shoul d be do ne with the and

keys.

4.4 SYSTEM men u
SYSTEM-- The following parameters are

used to control and provide in formation regarding the

over al l opera t ion of the un it:

4.5 AUDIO1 menu
AUDIO. 1. -- The following parameters

are used to control the audio operation of the unit

using the first audio menu:

Display Values

(*=default) Descri bed in
iD. sel.
(ID selection) 1* thro ugh 15 8 . 2. 2, “Set t ing
machine ID”
ID when t he unit is connect ed in a chain of DTRS units
time. mode.
(ti me mode) ABS*, TC 9.1, “ABS and
timecode”
Refer ence t iming s ource
CLOK. MODE
(clock mode) AUTO*, INDViD
(individual) 8.6, “I ndivid ual
clock mode”
Clock source for a slave unit.
Current position
corresponds to 23
Display shows 102
as the current value
Indicator
flashe s slowly
This position
corresponds
to 102
Current position
corresponds to 110
Display now shows 110
as the current value
Indicator
flashes fast as
soon as dial is
turned past
102 positi o n
This position
corresponds
to 102
PK. HLD
(pea k hold) 0, 1 through 9
seconds (default
is 3), CNT (contin-
uous)
7.8.1, “Pea k hold
time
Meter peak hold time
RLs.
(releas e t im e) FAST*, SLOW
(slow), MED
(medium)
7.8.2, “Mete r ballis-
tics”
Meter release tim e
save.
(save) OFF* 7.1 4, “Sav i ng set-
tings to tape”
Saves the current settings t o the tape
Load.
(loa d) OFF*7.15, “Restoring
settings from tape”
Loads settings from tape

Display Values

(*=default) Descri bed in
D. IN. TDIF (TDIF)*,
SPD (SPDIF) 5.3.1, “ Digita l input
selection”
Selects digital audi o source (for tracks 7 and 8 only)
IN. PATCH
(inp ut pat ch) ALL. ANALG* (all
analo g), ALL.
DGTL (all digital),
individual trac k s
set to A; (ana-
log), D; (d igital)
or T; (track)
5.3, “Input se lec -
tion
Track i nput so urce can be ei ther anal og, dig ital or a re corde d
track
TDIF.
(TDIF) 24*, 20
,
16 5.4.2, “Select ing
inpu t word length”
Input digi tal w ord le ngth
DITH
(dither) OFF*, RECT (rect-
angul ar), TRI (tri-
angul ar)
7.11.1, “ Select ing
dither settings ”
Dither no is e shape

Display Values