7Front and Rear Panels

Rear panel DIP switches (Phaser 220i)

Phaser 220i rear panel DIP switches

Switch

Function

Settings

 

 

 

1

Reset/run

Up: The printer resets and does not accept data

 

 

while the switch is in this position.

 

 

Down. The printer runs a self-test, then proceeds

 

 

to run normally. Leave the switch down for normal

 

 

operation.

 

 

 

2, 3, and 4

Configuration page

See the table, “Phaser 220i DIP Switches 2, 3, and

 

Sample prints

4” on page 7-5.

 

 

 

5

Start Job

Up: The Sys/Start job on the hard disk does

 

 

not run.

 

 

Down: The Sys/Start job runs.

 

 

 

6

Unused

 

 

 

 

7

Baud Rate

Up: Fixed. Sets the serial communication

 

 

parameters to 1200 baud, software flagging, and

 

 

ignore parity.

 

 

Down: Variable. Lets you change the serial

 

 

communication parameters. The factory setting is

 

 

9600 baud, software flagging, and ignore parity.

 

 

 

8 and 9

Color correction

See the table, “Phaser 220i DIP Switches 8 and 9”

 

 

on page 7-5.

 

 

 