12 - 1
12. OPTIONS AND AUXILIARY EQUIPMENT
12. OPTIONS AND AUXILIARY EQUIPMENT
WARNING
Before connecting any option or auxiliary equi pment, make sure that the charge
lamp is off more than 10 minutes after power-off, then confirm the voltage with a
tester or the like. Otherwise, you m ay get an electric shock.
CAUTION Use the specified auxiliary equipment and o pt io ns . Uns pecified ones may lead to a
fault or fire.
12.1 Options
12.1.1 Regenerative brake options
CAUTION The specified combinations of rege nerative brake options and servo ampl ifiers
may only be used. Otherwise, a fire m ay occur.
(1) Combination and regenerative po wer
The power values in the table are resistor-generated powers and not rated powers.
Regenerative power[W]
Servo amplifier Built-in regenerative
brake resistor
MR-RB032
[40 ]
MR-RB12
[40 ]
MR-RB32
[40 ]
MR-RB30
[13 ]
(Note)
MR-RB50
[13 ]
MR-RB31
[6.7 ]
(Note)
MR-RB51
[6.7 ]
MR-J2S-10B(1) 30
MR-J2S-20B(1) 10 30 100
MR-J2S-40B(1) 10 30 100
MR-J2S-60B 10 30 100
MR-J2S-70B 20 30 100 300
MR-J2S-100B 20 30 100 300
MR-J2S-200B 100 300 500
MR-J2S-350B 100 300 500
MR-J2S-500B 130 300 500
MR-J2S-700B 170 300 500
Note: Always install a cooling fan.
(Note) Regenerative power[W]
Servo amplifier External regenerative brake
resistor (Accessory)
MR-RB65
[8 ]
MR-RB66
[5 ]
MR-RB67
[4 ]
MR-J2S-11KB 500 (800) 500 (800)
MR-J2S-15KB 850 (1300) 850 (1300)
MR-J2S-22KB 850 (1300) 850 (1300)
Note: Values in parentheses assume the installation of a cooling fan.