12. OPTIONS AND AUXILIARY EQUIPMENT
12.2 Auxiliary equipment
Always use the devices indicated in this sec tion or equi vale nt. To co mply with the EN Stand ard or U L/C-
UL (CSA) Standard, use the products which conform to the corresponding standard.
12.2.1 Recommended wires
(1) Wires for power supply wiring
The following diagram shows the wires used for wiring. Use the wires given in this section or equivalent.
C
P
U
V
W
L11
L21
B1
B2
U
V
W
L1
L2
L3Motor
Brake unit or
Return converter N
1) Main circuit power supply lead
Power supply Servo amplifier
3) Motor power supply lead
Servo motor
Electro-
magnetic
brake
Encoder
Encoder cable
(refer to Section 12.1.4)
4) Regenerative brake option lead
5) Electromagnetic
brake lead
2) Control power supply lead
Regenerative brake option
4) Brake unit lead or
Return converter
Cooling fan
BU
BV
BW
Fan lead
Power supply
The following table lists wire sizes. The wires used assume that they are 600V vinyl wires and the
wiring distance is 30m(98.4ft) max. If the wiring distance is over 30m(98.4ft), choose the wire size in
consideration of voltage drop.
The alphabets (a, b, c) in the table correspond to the crimping terminals (Table 12.2) used to wire the
servo amplifier. For connection with the terminal block TE2 of the MR-J2S-100B or less, refer to
Section 3.9.
The servo motor side connection method depe nd s on the type and cap ac ity of th e serv o m oto r. R efe r to
Section 3.6.
To comply with the UL/C-UL (CSA) Standard, use UL-recognized copper wires rated at 60 (140 ) or
more for wiring.