12 - 43
12. OPTIONS AND AUXILIARY EQUIPMENT
(2) Wires for cablesWhen fabricating a cable, use the wire mode ls given in the following table or equiv alent:Table 12.3 Wires for option cables
Characteristics of one core
Type Model Length
[m(ft)] Core size
[mm2]Number
of Cores Structure
[Wires/mm]
Conductor
resistance[ /mm]
Insulation coating
ODd[mm] (Note 1)
(Note 3)
Finishing
OD [mm] Wire model
2 to 10
(6.56 to 32.8) 0.08 12
(6 pairs) 7/0.127 222 0.38 5.6 UL20276 AWG#28
6pair (BLAC)
MR-JCCBL M-L 20 30
(65.6 98.4) 0.3 12
(6 pairs) 12/0.18 62 1.2 8.2 UL20276 AWG#22
6pair (BLAC)
2 5
(6.56 16.4) 0.2 12
(6 pairs) 40/0.08 105 0. 88 7. 2 (Note 2)
A14B2343 6P
MR-JCCBL M-H 10 to 50
(32.8 to 164) 0.2 14
(7 pairs) 40/0.08 105 0. 88 8. 0 (Note 2)
A14B0238 7P
2 5
(6.56 16.4) 0.08 8
(4 pairs) 7/0.127 222 0.38 4. 7 UL20276 AWG#28
4pair (BLAC)
MR-JHSCBL M-L 10 to 30
(32.8 to 98.4) 0.3 12
(6 pairs) 12/0.18 62 1.2 8.2 UL20276 AWG#22
6pair (BLAC)
2 5
(6.56 16.4) 0.2 8
(4 pairs) 40/0.08 105 0. 88 6. 5 (Note 2)
A14B2339 4P
MR-JHSCBL M-H 10 to 50
(32.8 to 164) 0.2 12
(6 pairs) 40/0.08 105 0. 88 7. 2 (Note 2)
A14B2343 6P
2 5
(6.56 16.4) 0.2 8
(4 pairs) 40/0.08 105 0. 88 6. 5 (Note 2)
A14B2339 4P
Encoder cable
MR-ENCBL M-H 10 to 50
(32.8 to 164) 0.2 12
(6 pairs) 40/0.08 105 0. 88 7. 2 (Note 2)
A14B2343 6P
Communication
cable MR-CPCATCBL3M 3 (9.84) 0.08 6
(3 pairs) 7/0.127 222 0.38 4. 6 UL20276 AWG#28
3pair (BLAC)
MR-J2HBUS M
MR-J2HBUS M-A 20
(10 pairs) 6.1 UL20276 AWG#28
10pair (CREAM)
Q172J2BCBL M(-B)
Bus cable
Q173J2B CBL M
0.5 to 5
(1.64 to 16.4) 0.08 14
(7 pairs)
7/0.127 222 0.38 5.5 UL20276 AWG#28
7pair (CREAM)

Note 1: d is as shown below:

d

Conductor Insulation sheath

2: Purchased from Toa Electric Industry

3: Standard OD. Max. OD is about 10% greater.