3 - 22
3. SIGNALS AND WIRING
3.7 Servo motor with electromagnetic brake
CAUTION
Configure the electromagnetic brake c ircuit so that it is activated not o nly by the
interface unit signals but also by a forced stop (EM1).
EM1RA
24VDC
Contacts must be open when
servo-off, when an alarm occurrence
and when an electromagnetic brake
interlock (MBR).
Electroma
g
netic brake
Servo motor
Circuit must be
opened during
forced stop (EM1).
The electromagnetic brake is provide d for holding purpose and must not be us ed
for ordinary braking.
POINT
Refer to the Servo Motor Instruction Manual for specifications such as the
power supply capacity and operation delay time of the electromagnetic
brake.
Note the following when the servo motor equipped with electromagnetic brake is used for applications
requiring a brake to hold the motor shaf t (vertical lift applications):
1) Do not share the 24VDC interface power supply between the interface and electromag netic
brake. Always use the power supply designed exclusively for the electromagnetic brake.
2) The brake will operate when the power (24VDC) switches off.
3) Switch off the servo-on command after the servo motor has stopped.
(1) Connection diagram
MBR
COM
Servo amplifier Servo motor
B1
B2
Forced
stop
RA
24VDC
RA
VDD
(2) Setting
In parameter No.21 (electromagnetic brake sequence output), set the time delay (Tb) from
electromagnetic brake operation to base circuit shut-off at a servo off time as in the timing chart in (3)
in this section.