12 - 54
12. OPTIONS AND AUXILIARY EQUIPMENT
12.2.9 EMC filterFor compliance with the EMC directive of the EN standard, it is recommended to use the following filter.Some EMC filters are large in leakage current.:(1) Combination with the servo amplifier
Recommended filter
Servo amplifier Model Leakage current [mA]
Mass
[kg]([Ib])
MR-J2S-10B to MR-J2S-100B
MR-J2S-10B1 to MR-J2S-40B1 SF1252 38 0.75(1.65)
MR-J2S-200B MR-J2S-350B SF1253 57 1.37(3. 02)
MR-J2S-500B (Note) HF3040A-TM 1.5 5.5(12.13)
MR-J2S-700B (Note) HF3050A-TM 1.5 6.7(14.77)
MR-J2S-11KB (Note) HF3060A-TMA 3.0 10.0(22.05)
MR-J2S-15KB (Note) HF3080A-TMA 3.0 13.0(28.66)
MR-J2S-22KB (Note) HF3100A-TMA 3.0 14.5(31.97)
Note: Soshin Electric. A surge protector is separately required to use any of these EMC filters. (Refer to the EMC Installation
Guidelines.)
(2) Connection example
NFB
L1
L2
L3
L11
L21
L1
L2
L3
LINE LOAD
3-phase
200 to 230V AC,
1-phase
230VAC or
1-phase
100 to120VAC
EMC filter Servo amplifier
(Note 1) Power supply
(Note 2)
Note: 1. For 1-phase 230VAC power supply, connect the power supply
to L1,L2 and leave L3 open.There is no L3 for 1-phase 100 to 120VAC
power supply.
2. Connect when the power supply has earth.
L1
L2
L3
MC
(3) Outline drawing
23.0(0.906)
LABEL
LINELOAD
168.0(6.614)
L1'
L2'
L3'
L1
L2
L3
149.5(5.886)
LINE
(input side)
LOAD
(output side)
140.0(5.512)
156.0(6.142)
16.0(0.63)
42.0
8.5
SF1252
LABEL
LINELOAD
168.0(6.614)
L1'
L2'
L3'
L1
L2
L3
209.5(8.248)
LINE
(input side)
LOAD
(output side)
140.0(5.512)
156.0(6.142)
49.0
8.5
SF1253 [Unit: mm(in)]
(0.335)
(1.654) (0.335)
(1.929)
6.0(0.236) 6.0(0.236)