12 - 27
12. OPTIONS AND AUXILIARY EQUIPMENT
(4) Bus cable
CAUTION When fabricating the bus cable, do not make incorrect connection. Doing s o can
cause misoperation or explosion.
When fabricating this cable, use the reco mmended cable given in Se ction 12.2.1 and f abricate it in
accordance with the connection diagram shown in this section. The overall distance of the bus cable on
the same bus is 30m(98.4ft).
(a) MR-J2HBUS M-A
1) Model definition
Model:MR-J2HBUS M-A
05 Cable Length [m(ft)]
5
Symbol 0.5 (1.64)
5 (16.4)
1 (3.28)
1
2) Connection diagram
MR-J2HBUS M-A
PCR-S20FS(Connector)
PCR-LS20LA1(Case) 10120-6000EL(Connector)
10320-3210-000(Shell kit)
SD
LG
LG
RD
RD*
TD
TD*
LG
LG
EMG*
EMG
1
11
2
12
4
14
5
15
6
16
20 Plate
1
11
2
12
4
14
5
15
7
17