1 - 5
1. FUNCTIONS AND CONFIGURATION
1.3 Servo amplifier standard specifications
Servo Amplifier
MR-J2S-
Item
10B 20B 40B 60B 70B 100B200B 350B 500B 700B 11KB 15KB 22KB 10B1 20B1 40B1
Voltage/frequency 3-phase 200 to 230VAC,
50/60Hz or 1-phase 230VAC,
50/60Hz 3-phase 200 to 230VAC, 50/60Hz 1-phase 100 to
120VAC 50/60Hz
Permissible voltage
fluctuation
3-phase 200 to 230VAC:170
to 253VAC
1-phase 230VAC: 207 to
253VAC
3-phase 170 to 253VAC 1-phase 85 to
127VAC
Permissible frequency
fluctuation Within 5%
Power supply capacity Refer to Section 11.2
Power supply
Inrush current Refer to Section 11 .5
Control system Sine-wave PWM control, current control system
Dynamic brake Built-in
Protective functions
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal
relay), servo motor overheat protection, encoder fault protection, regenerative fault protection,
undervoltage, instantaneous power failure protection, overspeed protection, excessive error
protection
Structure Self-cooled, open (IP00) Force-cooling, open
(IP00) External Self-cooled,
open(IP00)
[]0 to 55 (non-freezing)
During
operation [] 32 to 131 (non-freezing)
[ ] 20 to 65 (non-freezing)
Ambient
temperature In storage []4 to 149 (non-freezing)
During
operation
Ambient
humidity In storage
90%RH or less (non-condensing)
Ambient Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude Max. 1000m (3280ft) above sea level
5.9 [m/s2] or less
Environment
Vibration 19.4 [ft/s2] or less
[kg] 0.7 0.7 1.1 1.1 1.7 1.7 2.0 2.0 4.9 7.2 16 16 20 0.7 0.7 1.1
Mass [lb] 1.5 1.5 2.4 2.4 3.75 3.75 4.4 4.4 10.8 15.9 35.3 35.3 44.1 1.5 1.5 2.4