E658130
■Input function selection from the
The function numbers selection of the RYn2 to RYn8 function valid from the command of the
boldface numbers. |
|
|
|
| ||
Positive logic | Negative logic | Function | Speed control | PM control | V/f | |
0 | 1 | No function is assigned | ●/● | ● | ● | |
2 | 3 | Forward run command | ●/● | ● | ● | |
4 | 5 | Reverse run command | ●/● | ● | ● | |
6 | 7 | Standby | ●/● | ● | ● | |
8 | 9 | Reset command | ●/● | ● | ● | |
10 | 11 | Preset speed command 1 | ●/● | ● | ● | |
12 | 13 | Preset speed command 2 | ●/● | ● | ● | |
14 | 15 | Preset speed command 3 | ●/● | ● | ● | |
16 | 17 | Preset speed command 4 | ●/● | ● | ● | |
18 | 19 | Jog run mode | ●/● | ● | ● | |
20 | 21 | Emergency stop by external signal * | ●/● | ● | ● | |
22 | 23 | DC braking command | ●/● | ● | ● | |
24 | 25 | 2nd acceleration/deceleration | ●/● | ● | ● | |
26 | 27 | 3rd acceleration/deceleration | ●/● | ● | ● | |
28 | 29 | 2nd V/F control mode switching | ●/● | ● | ● | |
32 | 33 | 2nd stall prevention level | ●/● | ● | ● | |
36 | 37 | PID control prohibition | ●/● | ● | ● | |
46 | 47 | External thermal error input | ●/● | ● | ● | |
48 | 49 | Forced local from communication | ●/● | ● | ● | |
50 | 51 | Operation hold (hold of | ●/● | ● | ● | |
52 | 53 | PID integral/differential clear | ●/● | ● | ● | |
54 | 55 | PID characteristics switching | ●/● | ● | ● | |
56 | 57 | Forced run operation | ●/● | ● | ● | |
58 | 59 | Fire speed operation | ●/● | ● | ● | |
60 | 61 | Acceleration/deceleration suspend signal | ●/● | ● | ● | |
62 | 63 | Power failure synchronized signal | ●/● | ● | ● | |
64 | 65 | My | ●/● | ● | ● | |
74 | 75 | Integrating wattmeter(kWh) display clear | ●/● | ● | ● | |
76 | 77 | Trace back trigger signal | ●/● | ● | ● | |
78 | 79 | ●/● | ● | ● | ||
prohibitive signal | ||||||
|
|
|
|
| ||
80 | 81 | Holding of | ●/● | ● | ● | |
82 | 83 | Holding of OUT terminal output | ●/● | ● | ● | |
88 | 89 | Frequency UP | ●/● | ● | ● | |
90 | 91 | Frequency DOWN | ●/● | ● | ● | |
92 | 93 | Clear frequency UP/DOWN | ●/● | ● | ● | |
96 | 97 | Coast stop command | ●/● | ● | ● | |
98 | 99 | Forward/reverse selection | ●/● | ● | ● | |
100 | 101 | Run/Stop command | ●/● | ● | ● | |
104 | 105 | Frequency setting mode forced switching | ●/● | ● | ● | |
106 | 107 | Frequency setting mode terminal block | ●/● | ● | ● | |
108 | 109 | Command mode terminal block | ●/● | ● | ● | |
110 | 111 | Parameter editing permission | ●/● | ● | ● | |
120 | 121 | Fast stop command 1 | ●/● | ● | ● | |
122 | 123 | Fast stop command 2 | ●/● | ● | ● | |
134 | 135 | Traverse permission signal | ●/● | ● | ● | |
136 | 137 | Low voltage operation signal | ●/● | ● | ● | |
140 | 141 | Forward deceleration | ●/● | ● | ● | |
142 | 143 | Forward stop | ●/● | ● | ● | |
144 | 145 | Reverse deceleration | ●/● | ● | ● | |
146 | 147 | Reverse stop | ●/● | ● | ● | |
152 | 153 | No.2 motor switching | ●/● | ● | ● | |
(AD2 + VF2 + OCS2) | ||||||
|
|
|
|
| ||
200 | 201 | Parameter editing prohibition | ●/● | ● | ● | |
202 | 203 | Parameter reading prohibition | ●/● | ● | ● |
* This function is not dependent on cmod.
- 22 -