E658130
5.5.11.Description of monitor code
Divide the monitor code (RWw n) into half and select the monitor value 1 (RWr n) from the lower 8 bits and the monitor value 2 (RWr n) from the upper 8 bits.
For Example: When output voltage is selected for the monitor value 1 and output torque is selected for the monitor value 2.
Address | Upper 8 bits | Lower 8 bits |
RWw n | Monitor value 2 | Monitor value 1 |
RWw n+4 | - | Monitor value 3 |
RWw n+5 | - | Monitor value 4 |
RWw n+6 | - | Monitor value 5 |
RWw n+7 | - | Monitor value 6 |
Monitor code (When an invalid monitor code is set up, monitor value fixes to 0.)
Code Number | Second Monitor Description | First Monitor Description | Unit | |
(upper 8 bits) | (lower 8 bits) | |||
|
| |||
00H | Output frequency | None monitor (Monitor value is 0) | 0.01Hz | |
(Only the second monitor ) | ||||
|
|
| ||
01H | Output frequency | Output frequency | 0.01Hz | |
02H | Output current | Output current | 0.01A | |
03H | Output voltage | Output voltage | 0.1V | |
04H | None monitor (Monitor value is 0) | None monitor (Monitor value is 0) | - | |
05H | Frequency command value | Frequency command value | 0.01Hz | |
06H | Output speed | Output speed | ||
07H | Output torque (With sign) | Output torque (With sign) | 0.1% | |
08H | DC voltage | DC voltage | 0.1V | |
09H | PBR load factor | PBR load factor | 0.1% | |
0AH | Motor overload factor | Motor overload factor | 0.1% | |
0BH・0CH | None monitor (Monitor value is 0) | None monitor (Monitor value is 0) | - | |
0DH | Input power | Input power | 0.01kW | |
0EH | Output power | Output power | 0.01kW | |
0FH | Input terminal information | Input terminal information | - | |
10H | Output terminal information | Output terminal information | - | |
11H | Output current | Output current | 0.1% | |
12H | Exciting current | Exciting current | 0.01A | |
13H | None monitor (Monitor value is 0) | None monitor (Monitor value is 0) | - | |
14H | Cumulative operation time | Cumulative operation time | 1h | |
15H・16H | None monitor (Monitor value is 0) | None monitor (Monitor value is 0) | - | |
17H | Accumulation power supply ON time | Accumulation power supply ON time | 1h | |
18H | Motor overload factor | Motor overload factor | 0.1% | |
19H | Integral input power | Integral input power | 1kWh | |
1AH | Integral output power | Integral output power | 1kWh | |
1BH | Analog input(VIA) | Analog input(VIA) | 0.01% | |
1CH | Analog input(VIB) (With sign) | Analog input(VIB) (With sign) | 0.01% | |
1DH | Analog input(VIC) | Analog input(VIC) | 0.01% | |
1EH・1FH | None monitor (Monitor value is 0) | None monitor (Monitor value is 0) | - | |
21H | Torque current (With sign) | Torque current (With sign) | 0.1% | |
22H | None monitor (Monitor value is 0) | None monitor (Monitor value is 0) | - | |
23H | Factory specific monitor | Factory specific monitor | ― | |
24H | PID feedback value | PID feedback value | 0.01Hz |
- 33 -