Before You Install Stratagy in Strata CTX...

please read and complete both sides of this checklist.

This checklist only highlights important installation information. Please reference the Stratagy IVP8 or
Stratagy DK Installation Guide for details on programming individual features, etc. Unless otherwise noted in
these instructions, references to Stratagy apply to both the StratagyDK (Release 3.3) and Stratagy IVP8
products.
CAUTION! After making any significant program changes to the Stratagy, it is recommended the system be
properly shut down and restarted. This copies the most current database to the
C:\Stratagy\Archive\Good directory for use by the Automatic System Recovery feature (see
“Automatic System Recovery” on page 42 in the StratagyIVP8 or Stratagy DK Installation Guide).
Failure to do so could result in the loss of cust omer information if the system loses power before it
is properly shutdown and rebooted.
1$UH\RXDZDUHRIWKHSUHVFULEHGKDQGOLQJSUHFDXWLRQVIRUWKH6WUDWDJ\"
Whenever handling Stratagy, always wear the anti-static wrist strap (included); keep the strap by the unit.
Always hold the unit by its edges. Remember that an electrostatic charge from your body, even your own
body oils can damage the Stratagy.
Never drop or jar the Stratagy! Care should be taken whenever handling the unit.
Temperature changes greater than 20°F cause condensation on Stratagys hard drive. If there is such a
temperature variation, wait 24 hours before installation.
Always keep the Stratagy in its individual shipping box until its time to install it in the Strata CTX.
Never transport the Stratagy inside the Strata CT X .
2'R\RXKDYHHYHU\WKLQJ\RXQHHGIRUSURJUDPPLQJ6WUDWDJ\XVLQJ6WUDWDJ\
$GPLQ"
Stratagy Admin Release 3 software is only supported with the Stratagy Flash, StratagyDK Release 3 and
StratagyIVP8. Use with any Release 2 Stratagy system may cause erratic behavior.
Local Administration? Yo ull need a PC, 5MB hard drive space, 3.5 1.44 floppy drive, and 580KB free
RAM. Youll also need a 9-pin null-modem serial cable o r Toshibas SG-ADMCBL cable to connect your PC
to the Stratagy.
Remote (modem) Administration? Use Stratag y Admin software with Stratagys internal (soft)
2400-baud modem. No additional equipment is necessary.
...or use Toshibas 9600 baud SG-FMOD modem or a Hayes-compatible, 14.4 baud, V32.bis modem
connected to Stratagys serial Port 2. Youll need a customer-supplied 9-pin serial cable.
3,VWKH6WUDWD&7;UHDG\"
Stratagy is compatible with all Strata CTXs. Strata CTX needs to recognize Stratagy’s DTMF signaling. An
ARCS card must be installed in the Strata CTX100 for this DTMF signaling. Strata CTX670 allows four DTMF
circuits in its default configuration.
Install and program an ARCS card in the Strata CTX100. When installed, the ARCS card by default allows
four circuits. Additional licenses may be required, depending upon the Strata CTX configuration and
applications.
Program slot in Strata CTX before installing the Stratagy. Refer to Strata CTX Programming Manual for
details.