Before You Install Stratagy in Strata DK...

please read and complete both sides of this checklist.

This checklist only highlights important installation information. Please reference the Stratagy IVP8 or Stratagy DK Installation Guide for details on programming individual features, etc. Unless otherwise noted in these instructions, references to Stratagy apply to both the Stratagy DK (Release 3.3) and Stratagy IVP8 products.

CAUTION! After making any significant program changes to the Stratagy, it is recommended the system be properly shut down and restarted. This copies the most current database to the C:\Stratagy\Archive\Good directory for use by the Automatic System Recovery feature (see “Automatic System Recovery” on page 42 in the Stratagy IVP8 or Stratagy DK Installation Guide). Failure to do so could result in the loss of customer information if the system loses power before it is properly shutdown and rebooted.

1 $UH￿\RX￿DZDUH￿RI￿WKH￿SUHVFULEHG￿KDQGOLQJ￿SUHFDXWLRQV￿IRU￿WKH￿6WUDWDJ\"

Whenever handling Stratagy, always wear the anti-static wrist strap (included); keep the strap by the unit.

Always hold the unit by its edges. Remember that an electrostatic charge from your body, even your own body oils can damage the Stratagy.

Never drop or jar the Stratagy! Care should be taken whenever handling the unit.

Temperature changes greater than 20°F cause condensation on Stratagy’s hard drive. If there is such a temperature variation, wait 24 hours before installation.

Always keep the Stratagy in its individual shipping box until it’s time to install it in the Strata DK.

Never transport the Stratagy inside the Strata DK.

2 'R￿\RX￿KDYH￿HYHU\WKLQJ￿\RX￿QHHG￿IRU￿SURJUDPPLQJ￿6WUDWDJ\￿XVLQJ￿6WUDWDJ\￿ $GPLQ"

Stratagy Admin Release 3 software is only supported with the Stratagy Flash, Stratagy DK Release 3 and Stratagy IVP8. Use with any Release 2 Stratagy system may cause erratic behavior.

Local Administration? You’ll need a PC, 5MB hard drive space, 3.5” 1.44 floppy drive, and 580KB free RAM. You’ll also need a 9-pin null-modem serial cable or Toshiba’s SG-ADMCBL cable to connect your PC to the Stratagy.

Remote (modem) Administration? Use Stratagy Admin software with Stratagy’s internal (soft) 2400-baud modem. No additional equipment is necessary.

...or use Toshiba’s 9600 baud SG-FMOD modem or a Hayes-compatible, 14.4 baud, V32.bis modem connected to Stratagy’s serial Port 2. You’ll need a customer-supplied 9-pin serial cable.

3 ,V￿WKH￿6WUDWD￿'.￿UHDG\"

Make sure Stratagy is compatible with your Strata DK. It works with Strata DK424i, DK424/DK280 and DK40i/DK40/DK16e/DK16 systems and DK24/DK56/DK96 with Release 4 software.

Always program Strata DK slot assignments before installing the Stratagy. Use these slot assignments:

DK424i/DK424

DK280 (R3 or Higher)

DK40i/DK40/DK16e/DK16

DK24/DK56/DK96

 

 

 

 

Use a universal slot,

Use any universal slot,

Use any expansion cabinet

Use any slot after slot 01.

starting with slot 12 or 13 (if

starting with slot 12 (if a

slot that takes an eight-port

 

an RSIU is in slot 11); never

PDKU or PEKU is in slot

card (except slot 18 in the

 

use slots 27, 28, 31, 37, 38,

11) or slot 13 (if an RSIU is

DK40i/DK40/DK16e).

 

47, 48, 51, 57, 58, 67, 68,

in slot 11); never use slots

 

 

71, 77, or 78.

31 or 51.

 

 

 

 

 

 

Be sure to set the correct code in Strata DK programming for the slot where Stratagy is installed.

Always remember to shut down Stratagy software before powering down Strata DK (see page 40 in the Stratagy IVP8 or Stratagy DK Installation Guide).