TABLE A.1 – TOTAL COMBINED LENGTH OF ELECTRODE AND WORK CABLES
Cable | Cable Size for | |
250 Amps | ||
Length | ||
100% Duty Cycle | ||
| ||
1 AWG | ||
1 AWG | ||
1/0 AWG |
CABLE INSTALLATION
Install the welding cables to your Ranger 250 as fol- lows.
1.The engine must be OFF to install welding cables.
2.Remove the flanged nuts from the output terminals.
3.Connect the electrode holder and work cables to the weld output terminals. The terminals are iden- tified on the case front.
4.Tighten the flanged nuts securely.
5.Be certain that the metal piece you are welding (the “work”) is properly connected to the work clamp and cable.
6.Check and tighten the connections periodically.
CAUTION
•Loose connections will cause the output terminals to overheat. The terminals may eventually melt.
•Do not cross the welding cables at the output termi- nal connection. Keep the cables isolated and sepa- rate from one another.
AUXILIARY POWER RECEPTACLES
The auxiliary power of the Ranger 250 consists of two 20
The auxiliary power capacity is 8,000 watts of 60 Hz,
two separate 120 VAC branch circuits (these circuits cannot be paralleled). Output voltage is within ±10% at all loads up to rated capacity.
The 120 VAC auxiliary power receptacles should only be used with
NOTE: The 240 VAC receptacle has two 120 VAC cir- cuits, but they are of opposite polarities and cannot be paralleled.
STANDBY POWER CONNECTIONS
The Ranger 250 is suitable for temporary, standby or emergency power using the engine manufacturer’s rec- ommended maintenance schedule.
The Ranger 250 can be permanently installed as a standby power unit for 240 VAC,
1.Install the
2.Take necessary steps to assure load is limited to the capacity of the Ranger 250 by installing a 35 amp, 240 VAC
Maximum rated load for each leg of the 240 VAC auxiliary is 33 amperes. Loading above the rated output will reduce output voltage below the allow- able ±10% of rated voltage, which may damage appliances or other
3.Install a 50 amp, 120/240 VAC plug (NEMA Type
4.Plug this cable into the 50 amp, 120/240 VAC receptacle on the Ranger 250 case front.