TROUBLESHOOTING & REPAIR |
|
|
|
| ||||||
Observe Safety Guidelines |
|
|
|
|
| TROUBLESHOOTING GUIDE | ||||
detailed in the beginning of this manual. |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| |||||
PROBLEMS | POSSIBLE AREAS OF |
| RECOMMENDED |
|
| |||||
(SYMPTOMS) | MISADJUSTMENT(S) |
|
| COURSE OF ACTION |
|
| ||||
|
|
|
|
|
|
|
|
| ||
|
| OUTPUT PROBLEMS |
|
|
|
|
|
| ||
Major physical or electrical damage | 1. Contact your local Lincoln | 1. Contact the Lincoln Electric |
| |||||||
is evident. |
| Authorized | Field | Service | Service Department at |
| ||||
|
| Facility. |
|
|
|
|
| |||
|
|
|
| |||||||
No welding output in all modes. | 1. Place the Welding Terminals | 1. Check for loose or faulty con- |
| |||||||
The engine operates normally. The |
| switch in the “WELD TERMI- | nections on the heavy current |
| ||||||
auxiliary output is normal. |
| NALS ON” position. If the prob- | carrying leads | between the |
| |||||
|
| lem is solved, the fault may be | output bridge, the power mod- |
| ||||||
|
| in the external control cable (if | ule, the choke, the shunt and |
| ||||||
|
| used), leads #2 and #4. | See | the output | terminals. | Check |
| |||
|
| the Wiring Diagram. |
|
| thermostat TS1 and associated |
| ||||
| 2. | With the engine at high | idle | wiring. | See | the | Wiring |
| ||
| Diagram. |
|
|
|
| |||||
|
| (3700RPM), the machine in the |
|
|
|
| ||||
|
|
|
|
|
|
| ||||
|
| Stick mode and the OUTPUT | 2. Check the Welding Terminals |
| ||||||
|
| CONTROL at maximum, check | switch and associated leads (2 |
| ||||||
|
| for the presence of approxi- | and 4). | See | the | Wiring |
| |||
|
| mately 80VDC (open | circuit | Diagram. |
|
|
|
| ||
|
| voltage) at the output terminals. | 3. If the correct OCV is present |
| ||||||
|
|
|
|
|
|
| ||||
| 3. | If the correct OCV is present at | when the | Welding Terminals |
| |||||
|
| the welding | output terminals, | switch is in the “WELD TERMI | - | |||||
|
| check the | welding | cables, | NALS ON” position, the By- |
| ||||
|
| clamps and electrode holder for | pass Board may be faulty. Also |
| ||||||
|
| loose or faulty connections. |
| check associated wiring. See |
| |||||
| 4. Air flow may be blocked or | the Wiring Diagram. |
|
| ||||||
|
|
|
|
|
| |||||
|
| restricted. |
|
|
| 4. Check gate leads (#23 and |
| |||
|
|
|
|
|
| #25) for loose or faulty connec- |
| |||
|
|
|
|
|
| tions. See the Wiring Diagram. |
| |||
|
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call