Lincoln Electric SVM150-A service manual Normal Weld Voltage Waveform Wire CV

Models: SVM150-A

1 134
Download 134 pages 22.75 Kb
Page 99
Image 99

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-49

F-49

TROUBLESHOOTING & REPAIR

NORMAL WELD VOLTAGE WAVEFORM (WIRE CV)

MACHINE LOADED TO 250 AMPS AT 28 VOLTS

0 volts

20V1ms

This is the typical DC voltage gener- ated from a properly operating machine. Note that each vertical divi- sion represents 20 volts and that each horizontal division represents 1 millisecond in time.

The machine was loaded with a resis- tance grid bank to 250 amps at 28 volts.

NOTE: Scope probes are connected at weld output terminals.

SCOPE SETTINGS

Volts/Div

20V/Div.

Horizontal Sweep

1 ms/Div.

Coupling

DC

Trigger

Internal

 

 

RANGER 250

Page 99
Image 99
Lincoln Electric SVM150-A service manual Normal Weld Voltage Waveform Wire CV, Machine Loaded to 250 Amps AT 28 Volts