Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
TROUBLESHOOTING & REPAIR
NORMAL WELD VOLTAGE WAVEFORM (WIRE CV)
MACHINE LOADED TO 250 AMPS AT 28 VOLTS
0 volts
20V1ms
This is the typical DC voltage gener- ated from a properly operating machine. Note that each vertical divi- sion represents 20 volts and that each horizontal division represents 1 millisecond in time.
The machine was loaded with a resis- tance grid bank to 250 amps at 28 volts.
NOTE: Scope probes are connected at weld output terminals.
SCOPE SETTINGS
Volts/Div | 20V/Div. |
Horizontal Sweep | 1 ms/Div. |
Coupling | DC |
Trigger | Internal |
|
|