TROUBLESHOOTING & REPAIR

NORMAL WELD VOLTAGE WAVEFORM (WIRE CV)

MACHINE LOADED TO 250 AMPS AT 28 VOLTS

0 volts

20V1ms

This is the typical DC voltage gener- ated from a properly operating machine. Note that each vertical divi- sion represents 20 volts and that each horizontal division represents 1 millisecond in time.

The machine was loaded with a resis- tance grid bank to 250 amps at 28 volts.

NOTE: Scope probes are connected at weld output terminals.

SCOPE SETTINGS

Volts/Div

20V/Div.

Horizontal Sweep

1 ms/Div.

Coupling

DC

Trigger

Internal

 

 

RANGER 250