Return to Section TOC
Return to Section TOC
Section TOC
Return to Master TOC
Return to Master TOC
Master TOC
TROUBLESHOOTING & REPAIR
POWER CAPACITOR REMOVAL AND REPLACEMENT (continued)
FIGURE F.24 – POWER CAPACITOR MOUNTING DETAILS
CLAMPS
POWER
CAPACITORS
VERTICAL
BAFFLE
PROCEDURE
Return to
1.Perform the Case Cover Removal proce- dure.
2.Perform the Power Module Capacitor Discharge procedure.
3.Label all leads for reassembly.
4.With the 7/16" wrench, remove the nuts, lock washers, and flat washers holding the leads and straps to the power capacitor terminals.
5.With the slot headed screw driver, loosen the clamps holding the capacitors to the vertical baffle.
6.Slip the capacitors out of the vertical baffle.
To reassemble, slide the capacitors into the verti- cal baffle, observe capacitor polarity and lead ori- entation, and tighten the holding clamps. Replace the leads and straps as labeled and tighten the fasteners to between 50 and 60
Return to Section TOC
Return to Master TOC