TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

 

 

Observe Safety Guidelines

 

detailed in the beginning of this manual.

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

ENGINE PROBLEMS

 

 

 

 

The engine will not go to high idle

1. Make sure the welding cables

1.

Check the

Current Sensing

when attempting to weld or when

and auxiliary power lead con-

 

Toroid leads for loose or faulty

the auxiliary power is loaded.

nections are tight.

 

connections.

See the

Wiring

Welding output and auxiliary power

 

 

Diagram.

 

 

outputs are normal when IDLER

 

2.

The Current

Sensing

Toroid

switch is in the " HIGH" position.

 

 

 

may be faulty.

 

 

 

 

 

 

 

3.

The Control Board may be

 

 

 

faulty.

 

 

 

 

 

 

The machine goes to low idle but

1. Make sure there is NOT an

1.

The idler solenoid linkage may

does not stay at low idle.

external load (auxiliary or weld)

 

be misadjusted or damaged.

 

connected to the Ranger 250.

2.

The idler solenoid lead connec-

 

 

 

 

 

tions (#210C and #215) may be

 

 

 

loose or damaged.

 

 

 

3.

Perform the

Idler Solenoid

 

 

 

Test.

 

 

 

 

4.

The Control Board may be

 

 

 

faulty.

 

 

 

 

 

 

 

 