F-47

F-47

TROUBLESHOOTING & REPAIR

NORMAL WELD VOLTAGE WAVEFORM (STICK CC)

MACHINE LOADED TO 250 AMPS AT 25 VOLTS

Trig +15V

CH1

 

 

0 volts

20V1ms

This is the typical DC open circuit out- put voltage generated from a properly operating machine. Note that each vertical division represents 20 volts and that each horizontal division rep- resents 1 millisecond in time.

The machine was loaded with a resis- tance grid bank to 250 amps at 25 volts.

NOTE: Scope probes are connected at weld output terminals.

SCOPE SETTINGS

Volts/Div

20V/Div

Horizontal Sweep

1 ms/Div.

Coupling

DC

Trigger

Internal

 

 

RANGER 250

Page 97
Image 97
Lincoln Electric SVM150-A service manual Normal Weld Voltage Waveform Stick CC, Machine Loaded to 250 Amps AT 25 Volts