Lincoln Electric SVM150-A service manual Normal Weld Voltage Waveform Stick CC

Models: SVM150-A

1 134
Download 134 pages 22.75 Kb
Page 97
Image 97

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-47

F-47

TROUBLESHOOTING & REPAIR

NORMAL WELD VOLTAGE WAVEFORM (STICK CC)

MACHINE LOADED TO 250 AMPS AT 25 VOLTS

Trig +15V

CH1

 

 

0 volts

20V1ms

This is the typical DC open circuit out- put voltage generated from a properly operating machine. Note that each vertical division represents 20 volts and that each horizontal division rep- resents 1 millisecond in time.

The machine was loaded with a resis- tance grid bank to 250 amps at 25 volts.

NOTE: Scope probes are connected at weld output terminals.

SCOPE SETTINGS

Volts/Div

20V/Div

Horizontal Sweep

1 ms/Div.

Coupling

DC

Trigger

Internal

 

 

RANGER 250

Page 97
Image 97
Lincoln Electric SVM150-A service manual Normal Weld Voltage Waveform Stick CC, Machine Loaded to 250 Amps AT 25 Volts