Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
TROUBLESHOOTING & REPAIR
IDLER SOLENOID TEST
WARNING
Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical trou- bleshooting assistance before you proceed. Call
TEST DESCRIPTION
This test will determine if the idler solenoid is capable of functioning when it is energized with 12VDC.
MATERIALS NEEDED
3/8" Wrench or socket wrench 9/16" Wrench
External 12VDC supply (30 amps) Diagonal cutters
Wiring Diagram
Volt/Ohmmeter
This procedure should take approximately 30 minutes to perform.