F-6

 

 

 

 

 

F-6

 

 

TROUBLESHOOTING & REPAIR

 

 

 

 

 

Observe Safety Guidelines

 

TROUBLESHOOTING GUIDE

 

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

 

No auxiliary power at the recepta-

1. The circuit breakers may be

1.

Check the wiring between the

 

 

cles. The welding output is normal

tripped. Reset if necessary.

 

auxiliary receptacles, the con-

 

 

and the engine operates normally.

2. Check for loose or faulty con-

 

nection studs, and the main sta-

 

 

 

 

tor. See the Wiring Diagram.

 

 

 

nections at the auxiliary recep-

 

 

 

 

 

 

 

 

 

 

 

 

tacles.

2.

Perform

the

Stator

Voltage

 

 

 

 

 

Test.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The machine has welding output

1. If a remote control unit is con-

1.

Check

the

OUTPUT

control

 

 

but no control of output in some or

nected, check the remote control

 

potentiometer and

related

 

 

all modes. The auxiliary power is

and related cable.

 

leads. See the Wiring Diagram.

 

 

normal.

2. Check the welding and work

2.

Check the shunt and associated

 

 

 

 

 

 

cables for loose or faulty con-

 

feedback leads. See the Wiring

 

 

 

nections.

 

Diagram.

 

 

 

 

 

 

3.

Check the voltage feedback

 

 

 

 

 

leads for loose or faulty connec-

 

 

 

 

 

tions. See the Wiring Diagram.

 

 

 

 

4.

Perform

the

Power

Module

 

 

 

 

 

Test.

 

 

 

 

 

 

 

5.

The Control Board may be

 

 

 

 

 

faulty.

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION