3.11Error Codes and Description 3 Diagnostic Programs
Satellite A100/A105 / TECRA A7 Maintenance Manual 67
09 CTR/STR Connection
Error
1. There is OC (Open Circuit) or
SC (Short Circuit) on the LPT
port CTR/STR.2. The external
fixture does not match with the
chosen version.
Check the external fixture and the
port pins, and repeat the test.
10 DTR/STR Connection
Error As above. As above.
11 Toshiba Fixture Error As above. As above.
08xx LAN Card
01
PCI bus Error during
device ID test Don’t Scan PCI device Don’t support PCI BIOS
02
PCI Ethernet card not
present during device ID
test Don’t find Net card Please insert Net cad
03
Intel PCI Ethernet card
not present during MAC
test
Don’t found Net Card, This Card
can’t be Read MAC by this
method
Please update net card or use
other method
09xx Keyboard
01
Keyboard Map & Stroke
Test Fail Keyboard Map & Stroke Test
fails. Check the KBD connection and
repeat the test.
03 Clock Line Test Fail Clock Line Test fails. As above.
04 Data Line Test Fail Data Line Test fails. As above.
05xx Mouse
01 Touch Pad Test Fail Touch Pad Test Fail Check the mouse connection and
repeat the test.
14xx IrDA Test
01 2400BPS Test Error Failure with the infrared port or
the configuration program is not
executed.
Rerun the configuration program
or check the infrared port.
02 9600BPS Test Error As above. As above.
03 19200BPS Test Error As above. As above.
04 38400BPS Test Error As above. As above.
05 57600BPS Test Error As above. As above.
06 115200BPS Test Error As above. As above.
07 0.576MBPS Test Error As above. As above.
08 1.152MBPS Test Error As above. As above.
09 4.000MBPS Test Error As above. As above.
10 Connect time out Failure with the infrared port or
the configuration program is not
executed.
Rerun the configuration program
or check the infrared port. Check
the master.
28xx 1394
01 Can not find IEEE1394
controller Don’t support 1394.
20xx IDE-HDD
01 Get Parameter Fail ! Wrong test parameters are input
by user. Reinput the correct parameters.