E6581738

3.3.ZSW Status Word Data

Bit

Valure

Name

Note

 

 

 

 

0

1

Ready To Switch-on

Power supply is switched on

0

Not Ready To Switch-on

-

 

 

 

 

 

1

1

Ready To Operate

Refer to control word, bit 1.

0

Not Ready To Operate

-

 

 

 

 

 

 

1

Operation Enabled

Drive follows setpoint.

2

(Refer to control word 1, bit 3)

 

 

0

Operation Disabled

-

 

 

 

 

 

3

1

Fault Present

VF-MB1/S15 tripped.

0

No Fault

VF-MB1/S15 is not tripped.

 

 

 

 

 

4

1

Coast Stop Not Activated

-

0

Coast Stop Activated (OFF 2)

"Coast Stop (OFF 2)" command is present.

 

 

 

 

 

5

1

Quick Stop Not Activated

-

0

Quick Stop Activated (OFF 3)

"Quick Stop (OFF 3)" command is present

 

 

 

 

 

 

1

Switching On Inhibited

Control word bit1 or 2 is set to 0

6

or fault trip has been acknowledged.

 

 

0

Switching On Not Inhibited

-

 

 

 

 

 

 

1

Warning Present

Drive still operational: Alarm in service parameter: No

7

acknowledgement.

 

 

0

No Warning

Alarm not present or alarm has disappeared again

 

 

 

 

 

 

1

Speed Error

Refer to section 3.3.1.

8

Within Tolerance Range

 

0

Speed Error

 

 

 

 

Out Of Tolerance Range

 

 

 

 

9

1

Control Requested

VF-MB1/S15 is controlled by PROFIBUS master.

0

No Control Requested

VF-MB1/S15 is controlled by another interface.

 

 

 

 

 

10

1

f Or n Reached Or Exceeded

Actual value ≥ Comparison value (setpoint)

0

f Or n Not Reached

-

 

 

 

 

 

11

----

Device-specification

(Reserved.)

 

 

 

 

12

----

Device-specification

(Reserved.)

 

 

 

 

13

----

Device-specification

(Reserved.)

 

 

 

 

14

----

Device-specification

(Reserved.)

 

 

 

 

15

----

Device-specification

(Reserved.)

 

 

 

 

- 11 -