SDSFE31xx-100 Industrial Device Server

Transition Networks

Connecting fiber cables

Fiber cable When connecting fiber cables to the 100BASE-FX port on the Device Server, make

installation sure the correct type is used: ST or SC.

To install the fiber cables, do the following:

Step

Action

1.Remove and keep the rubber fiber-port-protector cover shown below.

Note: When not connected to a fiber cable, insert the rubber protective cover into optic port to protect the optics.

2.

Check that the fiber terminators are clean. If necessary, clean the fiber connectors using locally accepted cleaning procedures.

Note: Dirty fiber connectors on fiber optic cables will impair light transmission quality through the cable and lead to degraded performance on the port.

3.

Connect the fiber cable as shown in Figure 11.

Figure 11: Fiber Cable Connections

4.

Check the corresponding fiber port LED on the Device Server to verify the connection—Link/Act LED should be lit.

Warning

Visible and invisible laser radiation when open: DO NOT stare into the beam, or directly view the beam with optical instruments. Failure to observe this warning could result in an eye injury or blindness.

Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure.

24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600