Transition Networks

SDSFE31xx-100 Industrial Device Server

Troubleshooting problem and corrective action table

Problem

Potential Cause

 

Potential Solution

Device Server does not

• Is the wired terminal-block plug

Wire and insert the terminal-block

power up

inserted into the Device Server?

 

plug into the Device Server’s

 

 

 

 

terminal block

 

 

• Is the power LED lit?

Check that DC power is at the

 

 

 

 

recommended levels.

 

 

 

Contact Technical Support.

 

 

 

 

US/Canada: 1-800-260-1312,

 

 

 

 

International: 00-1-952-941-7600

No activity at the DB-9

• Is the power LED lit?

Check the power is turned ON.

port

• Can the Device Server receive

Send link pass from the connected

 

 

link pulses?

 

device (if a computer, press any key

 

 

 

 

and the Device Server’s ACT LED

 

 

 

 

will flicker each time you press the

 

 

 

 

key.)

 

 

• Is the DB-9 cable properly

Verify that the cable at both ends is

 

 

installed at both ends?

 

installed properly

 

 

• Is the DB-9 cable good?

Check pin assignments

 

 

 

Contact Technical Support.

 

 

 

 

US/Canada: 1-800-260-1312,

 

 

 

 

International: 00-1-952-941-7600

No activity on the fiber

• Is the LNK/ACT LED lit

Ensure that the fiber optic cable is

port

(green)?

 

installed properly into the Device

 

 

 

 

Server and the compliant device

 

 

 

• Power up the compliant connected

 

 

 

 

device.

 

 

 

Contact Technical Support.

 

 

 

 

US/Canada: 1-800-260-1312,

 

 

 

 

International: 00-1-952-941-7600

 

 

 

 

 

58

24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600

Page 70
Image 70
Transition Networks RS-232-TO-100BASE-FX, SDSFE31XX-100 manual Troubleshooting problem and corrective action table