SDSFE31xx-100 Industrial Device Server

Transition Networks

Configuration software, continued

Serial port config submenu (continued)

Submenu Item

Description

DS/CR Modes (continued)

Converter Mode (CR) is used for serial tunneling

 

across an Ethernet network between two serial ports

 

to simulate a direct serial connection between the

 

devices. See Figure 23.

Figure 23: Serial Tunneling

 

Packet Mode of Serial

Default is disabled. This will be the setting for the

 

 

Input (enable/disable)

serial data arriving at the serial port in a bit stream.

 

 

 

Enable if serial data on the serial interface will be in

 

 

 

packet mode.

 

 

Packet Mode Inter-Packet

This time value (in milliseconds) is the delimiter

 

 

Timeout

timeout value between serial packets. This only

 

 

 

applies if packet mode of the serial input is enabled.

 

 

 

The value will largely depend on the serial device

 

 

 

connected to the Device Server or the field bus

 

 

 

protocol used (i.e., Modbus, etc.).

 

 

 

 

 

 

Continued on next page

24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600