Ultratec PRO80TM manual Troubleshooting ASCII Calls

Models: PRO80TM

1 70
Download 70 pages 50.45 Kb
Page 58
Image 58

Troubleshooting ASCII Calls

If you do not receive a clear message during an ASCII call, try:

Changing the parity setting to correct garbled strings of text.

Changing the duplex setting to correct no characters or double characters appearing when you type.

Changing the baud rate (110 or 300).

Changing the ASCII (ORIGINATE/ANSWER) setting.

If the code option is set to automatic and your Superprint Pro80 loses the ASCII connection, NO ASCII CONNECTION is displayed and Baudot is used.

If the code option is set to ASCII and your Superprint Pro80 loses the ASCII connection, it waits until the other person changes to ASCII or until you change the code option setting to automatic or Baudot.

If you are unable to make an ASCII connection, check to make sure your ASCII seek time is set to at least 3. You can also try increasing the seek time.

5 2 • U S I N G C O D E S