Setting the System Hold Time

Setting the System Hold Time

Menu

Program SysteMS

E

Select the system

E

Edit

Sys

Option

E

Set

Hold

Time

E

This setting controls how many seconds the scanner scans a system before moving to the next unlocked system. Enter a value from 0-255, then press E to save the setting.

Notes:

If you select 0, the scanner stays on the system for a minimal time (only long enough to check current system activity).

The default setting is 2 seconds for each system.

For conventional systems, all channels will be scanned at least one time regardless of this setting.

The scanner moves to the next system after the hold time expires, any current transmission ends, and the channel delay time expires.

Setting the Channel Delay Time

Menu

Program SysteMS

E

Select the system

E

Edit

Sys Option

E

Set

DELAY Time

E

This setting controls how many seconds the scanner waits after a transmission ends before resuming scanning. Enter a value from 1-5 or Off, then press E.

Notes:

The default setting is 2 seconds for each system.

This setting applies to all channels within the system.