If you experience difficulty while in TrunkTracker mode, try the following steps.
Problem |
| Suggestion |
Scanner won't track. | 1. | Missing the Data Frequency. |
| 2. | Change to a Type 1 Scanner setup. |
|
| Review Fleet Map Programming on page 44. |
|
|
|
Scanner won't stop | 1. | No IDs have been programmed. |
during Scan List mode. | 2. | The IDs you have stored are not active. |
|
| |
Scanner will not acquire | 1. Adjust the squelch for Trunking mode - refer to page 29. | |
data channel. | 2. | Missing the frequency used for the data channel. |
|
| Check your frequency list. |
|
|
|
Missing replies to | 1. | Change a Type 1 scanner setup. |
conversations. | 2. | Review Fleet Map Programming on page 44. |
| Try another Preset Fleet Map or Program your own Fleet | |
| 3. | Map. |
| Check to see that all of the system's frequencies have | |
|
| been entered. |
|
|
|
Channel Activity | 1. | May be a telephone interconnect call, which are |
Indicators are flashing | 2. | intentionally blocked by your scanner. |
but no sound is heard. | The ID on your display is not active. | |
|
|
|
| 1. | Logical channel numbers (frequencies) for the system are |
Scanner not tracking an |
| not programmed in the correct order. Check frequency |
EDACS system | 2. | resources and reprogram. |
properly. | Not all frequencies for the system are programmed. | |
|
| Check frequency resources. |
If you still cannot get satisfactory results while using your scanner or if you want additional information, please see the Uniden contact details in the warranty page at the back of this manual.