Vidikron Vision 100t Perform the adjustments in the order listed here, Below Black Above Black

Models: Vision 90t Vision 100t

1 76
Download 76 pages 43.91 Kb
Page 43
Image 43
Perform the adjustments in the order listed here.

Operation

Although it may be possible to obtain satisfactory picture quality using the naked eye and regular program material, Vidikron recommends using the following calibration tools for best results:

External test pattern source – Ovation Multimedia, Digital Video Essentials or AVIA test DVD or equivalent.

A blue filter (provided with many test DVDs), for color level and tint adjustments.

Connect your test pattern source to the input that you are calibrating and proceed as follows.

Perform the adjustments in the order listed here.

Brightness: On your external test pattern source, select a PLUGE pattern. (PLUGE is an acronym for “Picture Line-Up Generation Equipment.”) Figure 4-2shows a typical PLUGE pattern.

Below Black Below Black

Above Black

Figure 4-2. Typical PLUGE Pattern for Adjusting Brightness

PLUGE patterns vary but generally consist of some combination of black, white and gray areas against a black background. The example above includes two vertical bars and four shaded boxes.

Select Brightness from the Picture menu and press ENTER. Adjust the brightness so that:

The darkest black bars disappear into the background.

The dark gray areas are barely visible.

The lighter gray areas are clearly visible.

The white areas are a comfortable level of true white.

The image contains only black, gray and white (no color).

Vidikron Vision Model 90t and Model 100t Owner’s Operating Manual

33

Page 43
Image 43
Vidikron Vision 100t, Vision 90t manual Perform the adjustments in the order listed here, Below Black Above Black