Programmable Station Numbering

Tie-line

1.This function allows the system to have "Programmable station numbers", other than the "Hardwired station numbers" by programming.

The stations not registered for "Programmable Station Numbers" remain in the original "Hardwired Station Number".

2.Each station number can be programmed in the station number series of the exchanges A, B and C that have been determined by the function of the Selectable First Station Number.

1.Numbering schedules can be changed easily by pro- gramming in stead of rewiring.

2.Numbering schedule (such as 200's, 300's, 900's) is available for convenient office differentiation. (archi- tectual numbering). (Refer to Fig. 1)

<Fig. 1>

Hardwired

Programmed

 

station number

station number

 

2 0 1

2 0 1

 

2 0 2

2 0 2

Department 1

 

2 0 3

 

 

2 0 4

3 0 1

Department 2

2 0 5

3 0 2

 

3.Normally, station numbers which are included in a station paging zone must be sequential, but programm- able station numbers can be randomly included in a station paging zone. (Refer to Fig. 2)

4.Programming at station No. 200, 470 and 740 must set up in each exchange to change the station numbering.

Dialing

Exchange

Programmable station

 

No. 203

 

 

 

 

Circuit No. 201

 

 

(Hardwired station

 

 

number)

 

 

Circuit No. 203

 

 

(Hardwired station

 

 

number)

 

 

Programmable station

 

 

No. 201

5."Programmable station number" series for each exchange

<Fig. 2>

Hardwired

Programmed

 

station number

station number

 

2 0 1

2 0

1

 

2 0 2

2

3

1

Station

2 0 3

 

 

 

paging zone

2

4 1

 

<Fig. 3>

Hardwired

Programmed

station number

station number

2 0 0

 

2 0 1

2 0 3

2 0 2

 

2 0 3

2 0 1

3 2 6

 

3 2 7

 

<Example 1> With Personal Number

<Example 2> Without Personal Number

<Example 3>

 

Exchange

Hardwired

Programmed

Exchange

Hardwired

Programmed

Exchange

Hardwired

Programmed

station number

station number

station number

station number

station number

station number

 

 

 

A

200 ~ 455

200 ~ 469

A

100 ~ 355

100 ~ 399

A

200 ~ 399

200 ~ 499

B

470 ~ 725

470 ~ 739

B

400 ~ 655

400 ~ 699

B

500 ~ 755

500 ~ 799

C

740 ~ 995

740 ~ 999

C

700 ~ 955

700 ~ 999

C

800 ~ 999

800 ~ 999

(Standard)

6.People operating the intercom stations need not be aware of the Hardwired station numbers. However, care must be taken when programming using station No. 200 in the exchange, as hardwired station numbers must be used for that purpose.

– 86 –