Press-To-Talk Control
Touch dialing the specific station number.
One way conversation is activated wh ile the Press-To-Talk
bar is continuously depressed, same as the Press-To-Talk
(selected simplex) function, and a relay is activated with
continuous make-contact.
One way conversation is reversed when the Press-To-Talk
bar is released, and the relay is activated with break-contact.
Note.
1. Stations No.232 through No.239 (8 stations) are the
specific stations.
2. It is possible to use a relay make output for Door
Remote or for controlling Radio Transmitting/
Receiving Equipment through user provided inter-
face.
3. Th e r elay output of the Paging Interface Unit PI-62
is used for this purpose.
Adaption of this function permits the paging of only
all-call plus 23 zones (the paging of a ll-call + 31 zones
is impossible.)
A specific station
(No.232 - 239)
The relay of PI-62 unit
Control
PTT
– 25 –