VHX SERIES STEAMER - ELECTRICAL OPERATION

LED

STATUS

DESCRIPTION

ELECTRICAL COMPONENTS CONDITION

 

 

ON

OFF

 

 

 

 

 

 

 

 

N1

X

 

same as “state A”

 

 

 

 

 

 

N2

X

 

same as "state B"

 

 

 

 

 

 

N3

X

 

same as “state A”

 

 

 

 

 

 

N4

X

 

same as "state B

 

 

 

 

 

 

N5

X

 

Reset switch is/was momentarily

K3 energized - K3(1) CLOSE (locking circuit)

 

energized

 

 

 

 

 

 

 

 

 

N6

 

X

Aux Water level is satisfied.

K3 energized - K3(1) OPEN

 

(Amber WATER light OFF)

 

 

 

 

 

 

 

 

 

N7

X

 

Reset switch is/was momentarily

K4 energized - K4(1) CLOSE (locking circuit)

 

energized

 

 

 

 

 

 

 

 

 

N8

 

X

High Limit is satisfied.

K4 energized - K4(1) OPEN

 

(Amber HIGH PRESS OFF)

 

 

 

 

 

 

 

 

 

N9

X

 

same as “state A”

 

 

 

 

 

 

N10

X

 

High limit is satisfied and reset

K3(2) CLOSE

 

switch energized

 

 

 

 

 

 

 

 

 

N11

X

 

Aux Water level is satisfied and

K4(2) CLOSE, K5 energized

 

reset switch energized

 

 

 

 

 

 

 

 

 

N12

X

 

Air intake blower receiving power

K5(1) CLOSE

 

 

 

 

 

N13-N17 remain OFF

 

 

 

 

 

 

 

Air Pressure Switch Satisfied: (STATE D)

Assume water level control “LLCO” is satisfied (LLCO contacts closed)

N1 thru N12 same as “Reset Engaged: (state C)"

LED

STATUS

DESCRIPTION

ELECTRICAL COMPONENTS CONDITION

 

 

ON

OFF

 

 

 

 

 

 

 

 

N13

X

 

Air pressure switch satisfied

24V to ignition module (term 6)

 

 

 

 

 

N14

X

 

Ignition module PV coil energized

PV CLOSE, 24V to K7

 

 

 

 

 

 

 

 

Pilot gas valve is energized.

K7 energized K7(1) CLOSE, relay board timer

N15

X

 

Note: N15 and the pilot gas valve will

circuit energized and starts time count. K6

 

be ON for approximately 15 seconds,

energized K6(1) CLOSE, pilot gas valve coil

 

 

 

 

 

 

then turn OFF.

energized for 15 sec. only.

 

 

 

 

 

N16

X

 

Ignition module PV coil energized,

MV CLOSE, 24V to water level board LLCO

 

pilot ignition flame is detected

contacts

 

 

 

 

 

 

 

 

 

 

 

Water level board LLCO is satisfied

Main gas valve coil energized, main burner

N17

X

 

and main gas valve is receiving

 

lights and flame continues to be detected.

 

 

 

power.

 

 

 

 

 

 

 

 

 

Burner ON, Boiler Heating to generate steam: (STATE E)

All LED’s ON except N6 & N8, N15 (still OFF from state D)

Burner OFF, Boiler Pressure Satisfied: (STATE F)

These LED’s should be OFF - N6, N8, N9, , N10, N11, N12, N13, N14, N15 (still OFF from state D) N16 & N17 These LED’s should be ON - N1 thru N5, N7