VHX SERIES STEAMER - TROUBLESHOOTING

TROUBLESHOOTING

BOILER BASE CONTROLS

WARNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRE ELECTRICAL TESTS OR MEASUREMENTS WHILE POWER IS APPLIED TO THE MACHINE. EXERCISE EXTREME CAUTION AT ALL TIMES. IF TEST POINTS ARE NOT EASILY ACCESSIBLE, DISCONNECT POWER, ATTACH TEST EQUIPMENT AND REAPPLY POWER TO TEST.

Models with new style controls: Before performing any of the troubleshooting checks listed below, remove the cover from the main control box and check the condition of the LED’S on the relay board for the status of the condition or component in the operating sequence. By utilizing the troubleshooting LED’S, the Service Technician can quickly and easily determine if a component is functioning properly or in need of repair. Refer to "RELAY BOARD" under "ELECTRICAL OPERATION".

SYMPTOM

 

POSSIBLE CAUSES

 

 

 

Steamer does not operate.

1.

No power to steamer.

 

2.

F1 Fuse open.

 

3.

Malfunctioning power switch.

 

4.

Malfunctioning power switch latching relay (old style controls

 

 

only).

 

 

 

Steamer ON, cannot reset low water

1.

Low water level in boiler.

condition.

 

A. Water inlet valve(s) OFF.

 

 

B. Fill solenoid not receiving power, clogged or

 

 

malfunctioning.

 

2.

Manual blowdown valve on water level probe housing open.

 

3.

Improper ground.

 

4.

Lime scale build-up auxiliary water level probe.

 

5.

Malfunctioning reset switch.

 

6.

Malfunctioning auxiliary water level control board.

 

 

 

Steamer ON, cannot reset high pressure

1.

Excessive pressure in boiler.

condition.

2.

Malfunctioning reset switch.

 

3.

Malfunctioning high pressure limit switch.

 

4.

Malfunctioning pressure switch latching relay (old style controls

 

 

only).

 

 

 

Steamer ON, reset switch pressed but

1.

Blower malfunctioning or loose connection on blower cord.

blower does not operate when calling for

2.

24 VAC transformer malfunctioning.

heat.

3.

Malfunction in cycling pressure switch.

(boiler pressure within operating limits)

4.

Malfunctioning "Low Water" or "Hi Pressure" light not indicating

 

 

 

true condition.

 

5.

Blower relay malfunctioning (old style controls only).

 

 

 

Page 61 of 68

 

F24700 (October 2001)

 

Page 61
Image 61
Vulcan-Hart MHB24G, VHX24G5 manual Boiler Base Controls, VHX Series Steamer Troubleshooting