Vulcan-Hart MHB24G, VHX24G5 manual Boiler Blowdown Steamer Shut OFF

Models: VHX24G5 VHX24G MHB24G

1 68
Download 68 pages 8.1 Kb
Page 9
Image 9

VHX SERIES STEAMERS - OPERATION

1.With both timer knobs at the off position, open the compartment doors and observe that no steam has entered the cooking compartments, then close the doors.

2.Set both timer knobs at 2 minutes. The ready lights will go off, the cooking lights will come on, and steam will begin to enter the compartments.

3.After one minute, open each door and observe that steam has ceased to enter each compartment, cooking lights go back to ready, and one minute is remaining on each cook timer.

4.Close doors and steam generation and cook timing will resume. Observe the floor drain to ensure that live steam from compartments is being cooled by cold water from the cold water condenser solenoid valve.

5.When timer knobs reach "0", buzzers will sound, steam generation will cease, cooking lights will go off and ready lights will come on. To silence buzzers, turn timer knobs to off position.

6.During idle time or a cooking cycle, the heating system will cycle on and off as necessary to maintain steam pressure in the boiler.

7.Turn power switch off to remove power from the steamer.

BOILER BLOWDOWN AND

STEAMER SHUT OFF

Turn the steamer off at least once daily to blowdown the boiler. This will aid in the removal of sediment and scale build-up in the boiler.

NOTE: Boiler should be with-in normal operating pressures.

1.Turn power switch OFF.

2.Boiler blowdown sequence starts.

A.The blowdown/drain solenoid valve will be de-energized and the boiler will begin to drain.

B.The cold water condenser solenoid will operate, as needed, to condense steam and to cool the water going into the drain.

A.Boiler blowdown starts.

Page 9 of 68

 

F24700 (October 2001)

 

Page 9
Image 9
Vulcan-Hart MHB24G, VHX24G5 manual Boiler Blowdown Steamer Shut OFF