VHX SERIES STEAMER - TROUBLESHOOTING
COOKING COMPARTMENT CONTROLS
SYMPTOM |
| POSSIBLE CAUSES |
|
|
|
Cooking compartments do not operate. | 1. | No power to compartments. |
| 2. | Pressure in boiler is below compartment pressure switch |
|
| setting. |
| 3. | Door switch malfunction. |
| 4. | Timer malfunction. |
| 5. | Malfunctioning pressure switch in compartment. |
| 6. | Verify correct compartment wiring and functioning |
|
| components. |
|
|
|
Steam generated inside compartment | 1. | Steam supply solenoid not fully closing (clogged or dirty). See |
when timer is off. |
| "FILL AND COLD WATER SOLENOID VALVES" in "SERVICE |
|
| PROCEDURES AND ADJUSTMENTS". |
| 2. | Timer contacts 1 & 3 closed. |
|
|
|
Timer motor does not run. | 1. | Door open or door switch inoperative. |
| 2. | Timer not getting power. |
| 3. | Timer motor inoperative. |
|
|
|
Door not closing properly. | 1. | Door latch assembly malfunction or out of adjustment. See |
|
| "DOOR SEALING ADJUSTMENT" in "SERVICE |
|
| PROCEDURES AND ADJUSTMENTS" |
| 2. | Striker adjustment. See "DOOR LATCH ADJUSTMENT" in |
|
| "SERVICE PROCEDURES AND ADJUSTMENTS". |
|
|
|
Door won’t open. | 1. | Latch won’t release. See "DOOR LATCH ADJUSTMENT" in |
|
| "SERVICE PROCEDURES AND ADJUSTMENTS". |
|
|
|
Buzzer not operating. | 1. | Timer malfunction. |
| 2. | Buzzer malfunction. |
|
|
|
Compartment leaks water around door | 1. | Compartment drain screen clogged. |
or water accumulating in compartment . | 2. | Drain line obstructed or not to an open gap drain. |
| 3. | Steamer not level. |
|
|
|
Steam leaks around door. | 1. | Worn gasket - See "DOOR SEALING ADJUSTMENT" in |
|
| "SERVICE PROCEDURES AND ADJUSTMENTS". |
| 2. | Damaged gasket. |
| 3. | Drain line obstructed or not to an open drain. |
|
|
|
F24700 (October 2001) |
| Page 66 of 68 |
|