MAINTENANCE

MAINTENANCE

WARNING: THE OVEN AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING OR SERVICING THE OVEN. THE COOKING COMPARTMENT CONTAINS LIVE STEAM. STAY CLEAR WHEN OPENING DOOR.

CLEAN CYCLE DELIMING PROCEDURE

With the Programmable Control, select the Clean Cycle [Program Number 00 and CLEAN CYCLE DELIMING PROCEDURE or Program

Number 98 and Manual background]. [ CC ] will display as the Program Number, [ dSCL ] will display in the Temperature Display. Push Start Stop. The indicator light in the Start Stop key will light. For Manual Controls, turn the Selector Switch to dSCL.

1.The Steam Generator will drain, the oven will beep for 5 seconds, [ 40 ] will display in the Time Display and the indicator light in the Start Stop key will turn off.

2.If the filter system is installed in the water line to the steam generator, remove the cartridge from the housing, install the dip tube and add the appropriate amount of ScaleKleen descaling chemicals for the Combi Model as specified in Column D or E of the following table.

If there is no filter system installed in the water line to the steam generator, add the amount of vinegar equal to the Tank Volume as specified in Column B or C of the following table. Add the vinegar to the steam generator tank through the opening inside the oven cavity using the funnel and flexible tube provided with the oven.

CLEAN CYCLE DELIMING — TANK VOLUME AND CHEMICAL REQUIREMENTS

DO NOT EXCEED THE RECOMMENDED CHEMICAL CONCENTRATION

A.

B.

C.

D.

E.

 

TANK VOLUME

TANK VOLUME

QUANTITY OF 7 OZ. PACKETS

QUANTITY OF 2.2 LB. PACKETS

MODEL

(U.S. GALLONS)

(QUARTS)

OF SCALEKLEEN TO ACHIEVE

OF SCALEKLEEN TO ACHIEVE

 

 

 

7 oz. / gallon

2.2 lb / five gallons

 

 

 

 

 

VCG10H

1.6 gal

6.3 qt.

1.5 packets or 10.5 oz.

0.3 packets or 10.5 oz.

VCG10F

1.6 gal

6.3 qt.

1.5 packets or 10.5 oz.

0.3 packets or 10.5 oz.

VCG20H

2.6 gal

10.5 qt.

2.5 packets or 17.5 oz.

0.5 packets or 17.5 oz.

 

 

 

 

 

3.Press the START button. The door closes and locks, and the control cannot be interrupted until the Clean Cycle is finished. The oven cannot be turned off. If a power interruption occurs, the Clean Cycle will resume after power is restored. No other operations can be performed until the Clean Cycle is [ DONE ].

The timer will start counting down. The steam generator will fill with water until the water level controls shut off the fill.

The steam generator will heat and produce steam for 30 minutes. After 30 minutes, the steam generator heat goes off and the tank drains.

The Time Display will show 10 minutes. The timer will not count down.

The Steam Generator will fill and drain two times. The fill time is programmed for each model.

With the Time Display still showing 10 minutes, the time will now begin to count down while the Steam Generator heats and generates steam. At the end of the 10 minute interval, the Steam Generator heat goes off and the tank drains.

[ DONE ] will display in the Temperature Display indicating that the Clean Cycle is complete.

NOTE: If an error occurs during the Clean Cycle, [ FAIL ] will display in the Temperature Display instead of [ DONE ].

Per the instructions in the filter cartridge replacement and preventive maintenance kit: Retest the water, return the response card and replace the filter cartridge.