value. Press  TIME to advance to the next step.

7.[ uuuu ] is displayed in the TIME display and the maximum steam generator temperature setting is displayed in the TEMPERATURE display. This value must be adjusted for the elevation (see Elevation vs. Boiling Temperature Table, below). Rotate the adjustment knob

clockwise to increase or counterclockwise to decrease the numeric

value. Press Manual background TIME to advance to the next step.

ELEVATION

Sea Level

500 to

1000 to

2000 to

3000 to

4000 to

5000 to

6000 to

7000 to

8000 to

9000 to

Above

10,000

10,000

 

to 500 Ft.

1000 Ft.

2000 Ft.

3000 Ft.

4000 Ft.

5000 Ft.

6000 Ft.

7000 Ft.

8000 Ft.

9000 Ft.

Ft.

Ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BOILING

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE

212OF

211OF

209OF

207OF

205OF

204OF

202OF

200OF

198OF

196OF

195OF

194OF

(WATER)

 

 

 

 

 

 

 

 

 

 

 

 

OF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8.[ CCCC ] is displayed in the TIME display and the maximum convection

oven temperature setting is displayed in the TEMPERATURE display. This value can be adjusted from 482°F to 518°F. It is recommended the [ CCCC ] setting be 518°F. Rotate the adjustment knob

counterclockwise to decrease or clockwise to increase the numeric

value. Press Manual background TIME to advance to the next step.

9.Set the Minimum and Maximum Values in steps 10 and 11 according to the FAN MOTOR COEFFICIENTS TABLE, below, the motor manufacturer's label and the number of convection fan motors in the oven.

FAN MOTOR COEFFICIENTS TABLE

 

Number of

Minimum Value

Maximum Value

Motor Manufacturer(s)

Convection Fan

1 - -

2 - -

 

Motors

See step 10.

See step 11.

 

 

 

 

Leroy-Somer (Hanning)

1

08

60

Brook-Crompton

1

08

60

Both motors by Leroy-Somer (Hanning)

2

26

130

Both motors by Brook-Crompton

2

26

130

1 motor by Leroy-Somer (Hanning) and

2

26

130

1 motor by Brook Crompton

 

 

 

 

 

 

 

10.[ 1 - - ] is displayed in the TIME display and the Minimum Value is displayed in the TEMPERATURE display. Rotate the adjustment knob clockwise to increase or counterclockwise to decrease the Minimum

Value according to the table above. Press Manual background TIME to advance to the next step.

11.[ 2 - - ] is displayed in the TIME display and the Maximum Value is displayed in the TEMPERATURE display. Rotate the adjustment knob clockwise to increase or counterclockwise to decrease the Maximum

Value according to the table above. Press Manual background TIME to advance to the next step.

12.To repeat the Configuration Mode process from step 2, press Manual background. To exit Configuration Mode and save all settings, press the START button.