7.[ uuuu ] is displayed in the TIME display and the maximum steam generator temperature setting is displayed in the TEMPERATURE display. This value must be adjusted for the elevation (see Elevation vs. Boiling Temperature Table, below). Rotate the adjustment knob
clockwise to increase or counterclockwise to decrease the numeric
value. Press TIME to advance to the next step.
ELEVATION | Sea Level | 500 to | 1000 to | 2000 to | 3000 to | 4000 to | 5000 to | 6000 to | 7000 to | 8000 to | 9000 to | Above | |
10,000 | 10,000 | ||||||||||||
| to 500 Ft. | 1000 Ft. | 2000 Ft. | 3000 Ft. | 4000 Ft. | 5000 Ft. | 6000 Ft. | 7000 Ft. | 8000 Ft. | 9000 Ft. | Ft. | Ft. | |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |
BOILING |
|
|
|
|
|
|
|
|
|
|
|
| |
TEMPERATURE | 212OF | 211OF | 209OF | 207OF | 205OF | 204OF | 202OF | 200OF | 198OF | 196OF | 195OF | 194OF | |
(WATER) | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||
OF |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
8.[ CCCC ] is displayed in the TIME display and the maximum convection
oven temperature setting is displayed in the TEMPERATURE display. This value can be adjusted from 482°F to 518°F. It is recommended the [ CCCC ] setting be 518°F. Rotate the adjustment knob
counterclockwise to decrease or clockwise to increase the numeric
value. Press TIME to advance to the next step.
9.Set the Minimum and Maximum Values in steps 10 and 11 according to the FAN MOTOR COEFFICIENTS TABLE, below, the motor manufacturer's label and the number of convection fan motors in the oven.
FAN MOTOR COEFFICIENTS TABLE
| Number of | Minimum Value | Maximum Value | |
Motor Manufacturer(s) | Convection Fan | 1 - - | 2 - - | |
| Motors | See step 10. | See step 11. | |
|
|
|
| |
1 | 08 | 60 | ||
1 | 08 | 60 | ||
Both motors by | 2 | 26 | 130 | |
Both motors by | 2 | 26 | 130 | |
1 motor by | 2 | 26 | 130 | |
1 motor by Brook Crompton | ||||
|
|
| ||
|
|
|
|
10.[ 1 - - ] is displayed in the TIME display and the Minimum Value is displayed in the TEMPERATURE display. Rotate the adjustment knob clockwise to increase or counterclockwise to decrease the Minimum
Value according to the table above. Press TIME to advance to the next step.
11.[ 2 - - ] is displayed in the TIME display and the Maximum Value is displayed in the TEMPERATURE display. Rotate the adjustment knob clockwise to increase or counterclockwise to decrease the Maximum
Value according to the table above. Press TIME to advance to the next step.
12.To repeat the Configuration Mode process from step 2, press . To exit Configuration Mode and save all settings, press the START button.
– 37 –