2 1 2•F

STEAMING (Steam Mode only)

Steam Mode will not begin if cavity temperature is above 212°F (100°C).

Steam cooking is used for stewing, poaching and gentle cooking of products cooked in water. Steam flows without pressure into the oven. The fan circulates the steam to all parts of the oven. Allow the steam generator to preheat for 4 to 5 minutes if starting from cold.

Automatic Steaming can be set up so the buzzer sounds when the Cooking Time has elapsed or when the product's internal temperature has reached the Probe Temperature set point. If using the Probe Temperature, insert the probe near the center of the product. Cooking Time is not used when the Probe Temperature is in use.

Usually, the Cooking Time and Oven Temperature are used to control the steaming process.

Alternatively, the Probe Temperature can be used to indicate when cooking is done. When using the

Probe Temperature, either the Oven Temperature or 1 h 7 0 min can be used to control the oven.

h 1 0 min

TIME DOWN UP PROBE

2 1 2F

Turn the oven ON.

Select Steam Mode.

For standard automatic steaming, set the Cooking Time and the Oven Temperature.

To set the Cooking Time, press Manual background and use the UP and DOWN arrows.

To set the Oven Temperature, press Manual background and use the UP and DOWN arrows to adjust the setting.

TEMP DOWN UP

1 h 7 0 min

TIME DOWN UP PROBE

For final product temperature steaming, set the Probe Temperature.

To set the Probe Temperature, press Manual background and use the UP and DOWN arrows. When the Probe Temperature indicator is lit,

the numeric value in the time display is the Probe Temperature

in °F. Probe Temperature can be used with either Manual background or

Manual background.

When the control is set, load the oven. If using the probe, place it in the center of the product.

Close the door and press Manual background to begin.

Upon completion of the steaming process, when either the Cooking Time has counted down or the Probe Temperature has been reached, the buzzer will sound.

Press Manual backgroundto silence the buzzer. Check the product for doneness.

– 20 –

Page 20
Image 20
Vulcan-Hart VCG10H, VCG10F, VCG20H, ML-126836, ML-126837, ML-126838 operation manual 2 1 2 F, 1 h 7 0 min