EXAMPLE PROGRAM
This example shows how to program a
The first item in the table on page 23 provides the information: Refer to the menu card example at the bottom of page 25.
Phase 1 | Phase 2 |
Convection 425OF
10 minutes
COMBI 280OF
Steam Factor 50
Final Internal Temperature:
Probe Setting 140OF
Turn the oven ON.
Phase 1 Convection HOT AIR Mode by pressing. The first light blinks on the phase button to indicate that you are programming Phase 1.
| Press | : The Temperature displays 302°F. Press | to increase or | to | |||||
| decrease until the Temperature displays 425°F. |
|
|
| |||||
| Press | and press | to increase or | to decrease until the Time displays | |||||
| [ – h 10 min ]. |
|
|
|
|
|
|
| |
| Press | to shift to Phase 2: The second indicator light begins to flash. |
| ||||||
Phase 2 |
|
| 3 times. The first | ||||||
Select Combi Mode - Steam Factor of 50 by pressing |
|
| |||||||
| four indicator lights will be lit to indicate the Steam Factor equals 50. |
| |||||||
| Press | : The Temperature displays 302°F. Press | to increase or | to | |||||
| decrease until the Temperature displays 280°F. |
|
|
| |||||
| Press | and press | to increase or | to decrease until the Probe Temperature | |||||
| displays 140°F. |
|
|
|
|
|
|
| |
| Press | to shift to Phase 3: The third indicator light begins to flash. |
| ||||||
Save | Press the | key and press | to increase or | to decrease until the | |||||
| Program Number displays | . Verify that this program number is vacant, or | |||||||
| choose a different program number that is vacant. A vacant program displays the | ||||||||
| current temperature and blank Time [ – h – – min ]; no Mode or Phase indicator lights | ||||||||
| are lit. Then press | until the beep is heard and the program is saved in memory. |
– 24 –