Vulcan-Hart VCG10H, VCG10F, VCG20H, ML-126836, ML-126837, ML-126838 Example Program, Phase, Save

Models: VCG10H ML-126836, VCG10F ML-126837, VCG20H ML-126838 VCG10H, VCG10F, VCG20H, ML-126836, ML-126837, ML-126838

1 40
Download 40 pages 4.87 Kb
Page 24
Image 24
EXAMPLE PROGRAM

EXAMPLE PROGRAM

This example shows how to program a two-phase process for cooking Roast Beef and store it as program number 20.

The first item in the table on page 23 provides the information: Refer to the menu card example at the bottom of page 25.

Phase 1

Phase 2

Convection 425OF

10 minutes

COMBI 280OF

Steam Factor 50

Final Internal Temperature:

Probe Setting 140OF

Turn the oven ON.

Phase 1 Convection HOT AIR Mode by pressingPhase 2. The first light blinks on the phase button Save to indicate that you are programming Phase 1.

 

Press

: The Temperature displays 302°F. Press

to increase or

to

 

decrease until the Temperature displays 425°F.

 

 

 

 

Press

and press

to increase or

to decrease until the Time displays

 

[ – h 10 min ].

 

 

 

 

 

 

 

 

Press

to shift to Phase 2: The second indicator light begins to flash.

 

Phase 2

 

 

3 times. The first

Select Combi Mode - Steam Factor of 50 by pressing

 

 

 

four indicator lights will be lit to indicate the Steam Factor equals 50.

 

 

Press

: The Temperature displays 302°F. Press

to increase or

to

 

decrease until the Temperature displays 280°F.

 

 

 

 

Press

and press

to increase or

to decrease until the Probe Temperature

 

displays 140°F.

 

 

 

 

 

 

 

 

Press

to shift to Phase 3: The third indicator light begins to flash.

 

Save

Press the

key and press

to increase or

to decrease until the

 

Program Number displays

. Verify that this program number is vacant, or

 

choose a different program number that is vacant. A vacant program displays the

 

current temperature and blank Time [ – h – – min ]; no Mode or Phase indicator lights

 

are lit. Then press

until the beep is heard and the program is saved in memory.

– 24 –

Page 24
Image 24
Vulcan-Hart VCG10H, VCG10F, VCG20H, ML-126836, ML-126837, ML-126838 operation manual Example Program, Phase, Save