PROGRAMMING MEMORY

PROGRAMMING MEMORY

Up to 99 Cooking Programs with up to 5 Phases in each program can be keyed-in and stored in Memory. Each program is accessed by its identifying number. Program numbers range from 00 – 98. A pre-defined Clean Cycle Deliming program is also available (refer to page 38).

If the numbered Program has not been programmed (or is vacant), the Time displays – h – – min. No Mode or Phase indicator lights are lit. The Temperature displays – – or the current temperature.

To CREATE a new program —

0 0

With — — in the program number display, the control is in Non-

Program mode.

 

— —

Press the key. Program Number 00 is displayed and the control

ENTER

is now in Program Mode. Use UP or DOWN arrows to increase or decrease the program number until a vacant program number is found.

DOWN

UP

ENTER THE COOKING INSTRUCTIONS (FOLLOW STEPS 1 – 6):

 

 

1)Select the cooking mode: Hot Air, Steam or Combi. If Combi, set Steam Factor.

2)Set either the Time or Probe Temperature.

3)Set the Oven Temperature or Manual background.

4)End of the 1st Phase. Press Manual background to shift to the next phase.

5)Repeat steps 1 – 4 for as many of the 5 phases as are needed. Review the program by stepping through the phases. Make any needed changes.

6)When the program is set, save it in memory by pressing Manual background until the beep is heard.

NOTE: A cooking program can also be entered in manual mode and saved to a

program number by selecting the Program Number and pressing Manual background for about three seconds.

To DELETE an existing program —

ENTER

Manual background 0 0

— —

DOWNUP

With — — in the program number display, the control is in Non- Program mode.

Press the Manual background key. Program Number 00 is displayed and the control is in Program Mode. Use UP or DOWN arrows to increase or decrease the program number until the program number to be deleted is displayed.

Press Manual background and hold it in for about three seconds until the beep sounds, indicating the program has been deleted.

NOTE: If a previous program had been selected and was active in Non-Program mode, it will be copied to the selected program number, replacing the previous program. Verify that the program number is vacant after you delete it.