VXI Technology, Inc.

0x0022 = 100 Ω Range Resistance Measurement - Offset Method (2-wire) 0x0023 = 1 kΩ Range Resistance Measurement - Offset Method (2-wire) 0x0024 = 10 kΩ Range Resistance Measurement - Offset Method (2-wire) 0x0025 = 100 kΩ Range Resistance Measurement - Offset Method (2-wire) 0x0026 = 1 MΩ Range Resistance Measurement - Offset Method (2-wire)

0x0027 = Auto-Range Resistance Measurement - Offset Method (2-wire) 0x0028 = 100 Ω Range Resistance Measurement - Offset Method (4-wire) 0x0029 = 1 kΩ Range Resistance Measurement - Offset Method (4-wire)

0x002A = 10 kΩ Range Resistance Measurement - Offset Method (4-wire) 0x002B = 100 kΩ Range Resistance Measurement - Offset Method (4-wire) 0x002C = 1 MΩ Range Resistance Measurement - Offset Method (4-wire)

0x002D = Auto-Range Resistance Measurement - Offset Method (4-wire) 0x002E = 100 Ω Range Resistance Measurement - Dynamic Method (2-wire) 0x002F = 1 kΩ Range Resistance Measurement - Dynamic Method (2-wire) 0x0030 = 10 kΩ Range Resistance Measurement - Dynamic Method (2-wire) 0x0031 = 100 kΩ Range Resistance Measurement - Dynamic Method (2-wire) 0x0032 = 1 MΩ Range Resistance Measurement - Dynamic Method (2-wire) 0x0033 = Auto-Range Resistance Measurement - Dynamic Method (2-wire) 0x0034 = 100 Ω Range Resistance Measurement - Dynamic Method (4-wire) 0x0035 = 1 kΩ Range Resistance Measurement - Dynamic Method (4-wire) 0x0036 = 10 kΩ Range Resistance Measurement - Dynamic Method (4-wire) 0x0037 = 100 kΩ Range Resistance Measurement - Dynamic Method (4-wire) 0x0038 = 1 MΩ Range Resistance Measurement - Dynamic Method (4-wire) 0x0039 = Auto-Range Resistance Measurement - Dynamic Method (4-wire)

Captured Data Calculations

The following commands perform calculations on previously captured data:

:

0x0001 = Peak Voltage

0x0002 = DC Voltage

0x0003 = RMS Voltage

0x0004 = Peak-to-Peak Voltage

0x001A = Minimum Voltage Calculation

0x001B = Generic Resistance Calculation

The user sets the Sampling Rate, Sampling Points, Measurement (voltage, resistance), Range and Trigger Event (signal or forced), collects the data. Once the data collection is complete, one of the above commands is issued. The microprocessor performs the calculation based on the captured data and returns the result in the Results Register.

Note that after data is collected, calculations can be performed without doing additional data captures. So, for example, it is possible to calculate dc voltage and then calculate peak-to-peak voltage on the same data collection.

42

SVM2608 Programming

Page 42
Image 42
VXI SVM2608 user manual Captured Data Calculations