www.vxitech.com

OPTION 1 - SVM2608-01

NUMBER OF CHANNELS

 

2

VMEBUS INTERFACE

 

 

Address Mode

A32

Data Transfer Mode

D16 or D32

SAMPLING RATE

 

 

Range

 

7.15 Samples/s to 20.0 MSamples/s

Resolution

 

8.333 ns

Accuracy

1%

MEMORY

 

 

 

1 MSamples per channel

VOLTAGE MEASUREMENTS

 

 

Range

±0.5 V, ±1.0 V, ±2.0 V, ±5.0 V, ±10.0 V, ±20.0 V

Resolution

Range/211

Accuracy

1%

INPUT IMPEDANCE

 

 

 

1 MΩ or 50 Ω (software selectable)

INPUT MODE

 

 

 

ac or dc (software selectable)

INPUT FILTER

 

 

 

 

5 MHz (-3 dB)

TRIGGER LEVELS

 

 

Internal

 

trigger level determined by selected voltage range (see Voltage Measurement above)

Range

 

Trigger level resolution

 

Full scale/211

Level accuracy

1%

External

 

 

Range

 

-10 V to +10 V

Trigger level resolution

 

4.88 mV

Level accuracy

1%

DELAYED TRIGGER

 

 

Range

 

0 samples to (224 -1) samples

Resolution

 

1 sample

TRIGGER ACCURACY

 

 

 

1%

EXTERNAL TRIGGER ACCURACY

 

1%

TIMEOUT

 

 

Range

 

10 µs to 227 hrs

Resolution

 

10 µs to 100 s

WARM-UP TIME

10 min

MTBF

80,000 hrs (based on 20% Ground Mobile, 80% Ground Fixed environment, T ≥ 52°C)