Wayne-Dalton 9600 Attaching Disconnect Cables, Mounting Disconnect, Handle Bracket

Models: 9600

1 40
Download 40 pages 4.99 Kb
Page 26
Image 26
Attaching Disconnect Cables

26

Tools Needed:

Pliers

Attaching Disconnect Cables

NOTE: See idrive® main installation and owners manual for idrive® parts.

Attach the loose disconnect cable (located in opener hardware bag) to the opener with the “S” hook. Close both ends of the “S” hook (with pliers) to lock assembly together.

Thread the disconnect cable (behind the counterbalance cable) through the hole in the right hand end bracket; remove all slack between opener and right end bracket.

 

S-Hook

 

Disconnect

 

Cable

 

Hole in Right

 

End Bracket

Right Side of

 

End Bracket

 

Hole in

Close “S” Hook

End Bracket

 

27

Mounting Disconnect

Handle Bracket

Tools Needed:

NOTE: See idrive® main installation and

Pencil

owners manual for idrive® parts.

Tape measure

Mark a location on the right jamb, 6

1/8” Drill Bit

feet above the floor to mount the

7/16” Socket

disconnect handle bracket.

 

Driver

Drill 1/8” pilot holes for the lag screws.

Power Drill

 

Align top of the bracket with the mark. Fasten bracket to the jamb with

(2) 1/4” x 1-1/2" lag screws.

6ft

(2) 1/4” x 1-1/2” Lag Screws

Disconnect

Handle Bracket

26

Please Do Not Return This Product To The Store. Contact your local Wayne-Dalton dealer. To find your local Wayne-Dalton dealer, refer to your

local yellow pages/business listings or go to the Find a Dealer section online at www.Wayne-Dalton.com

Page 26
Image 26
Wayne-Dalton 9600 installation instructions Attaching Disconnect Cables, Mounting Disconnect, Handle Bracket