Wayne-Dalton 9600 installation instructions Rear Support Continued, Installation

Models: 9600

1 40
Download 40 pages 4.99 Kb
Page 31
Image 31
Rear Support Continued...

 

Rear Support Continued...

 

 

 

nuts (may not be supplied), fabricate

Sound Framing Members

 

Tools Needed:

 

 

rear support for horizontal tracks. Attach

 

 

 

 

 

 

horizontal tracks to the rear supports with

 

 

 

5/16”-18 x 1-1/4” hex bolts and nuts

 

 

 

(may not be supplied). Horizontal tracks

 

 

 

must be level and parallel with door.

 

30” ANGLE - BOLTED

 

NOTE: If rear supports are to be installed

12” ANGLE

USING (2) 5/16” X 1-5/8”

 

over drywall, use 5/16” x 2” hex head lag

 

HEX HEAD LAG SCREWS

 

screws.

 

TO CEILING MEMBER AND

 

NOTE: If an idrive® opener will be

 

PARALLEL TO DOOR

 

installed, position horizontal tracks one

 

 

 

hole above level when securing it to rear

 

BOLT MUST EXTEND INTO

 

supports.

HORIZONTAL TRACK

 

Adjust weather seal (if necessary).

 

THE TRACK TO SERVE AS

 

Permanently attach the weather seal to

 

A ROLLER STOP

 

both door jambs and header. (Temporarily

 

 

 

attached in PREPARING THE OPENING on

Sound Framing Members

 

 

page 10.) Avoid pushing weather seal too

 

 

tightly against face of door.

 

 

 

Now, lift door and check it’s balance.

 

 

 

WARNING

 

 

 

Prior to winding or making adjustments

 

30” ANGLE - BOLTED

 

to the springs, ensure you’re winding

12” ANGLE

USING (2) 5/16” X 1-5/8”

 

in the proper direction as stated in the

HEX HEAD LAG SCREWS

 

 

 

Installation Instructions. Otherwise

 

TO CEILING MEMBER

 

the spring fittings may release from

 

AND PARALLEL TO DOOR

 

spring if not wound in the proper

 

 

 

direction and could result in severe or

HORIZONTAL TRACK

 

 

fatal injury.

BOLT MUST EXTEND INTO

 

Adjust, if door lifts by itself (hard to pull

 

THE TRACK TO SERVE AS

 

down) or if door is difficult to lift (easy to

 

A ROLLER STOP

 

pull down). Anytime spring adjustments

PERFORATED ANGLE

 

 

are made you must loosen the lock nuts

 

 

 

 

 

and retighten both lock nuts afterwards.

 

 

 

To adjust spring(s), only add or remove

 

 

 

1/4 turn on the counter at a time. Adjust

 

weather

 

both sides equally.

 

 

IMPORTANT: Do not add or remove

 

seal

 

 

 

 

more than 1 spring turn from

 

 

 

specified amount. If the door still

 

 

 

does not operate easily, lower

 

jamb

 

the door into the closed position,

 

 

UNWIND SPRING(S) TO ZERO, and

(3) 5/16”

 

 

recheck the following items:

 

 

1.) Check the door for level.

BOLTS & NUTS

permanently attached

 

2.) Check the TorqueMaster® spring tube

weather seal or door stop

 

and flagangles for level and plumb.

 

 

 

3.) Check the distance between the

 

 

 

flagangles - must be door width

 

 

 

plus 3-3/8” to 3-1/2”.

 

 

 

4.) Check the counterbalance cables

 

 

 

for equal tension - adjust if

 

 

 

necessary.

 

 

 

5.) Rewind the spring(s).

 

 

 

6.) Make sure door isn’t rubbing on

 

 

 

jambs.

 

 

 

NOTE: As a safety feature, the right hand end

 

 

 

bracket cannot be disassembled for service

 

 

 

until the spring is completely unwound and the

 

 

 

counter cover reads zero.

 

 

 

After door installation is completed, refer to the

 

 

idrive® owner’s manual.

31

INSTALLATION

Please Do Not Return This Product To The Store. Contact your local Wayne-Dalton dealer. To find your local Wayne-Dalton dealer, refer to your

local yellow pages/business listings or go to the Find a Dealer section online at www.Wayne-Dalton.com

Page 31
Image 31
Wayne-Dalton 9600 installation instructions Rear Support Continued, Installation