10
RF Laser Setup Parameters
Channel
Default Channel 0
The default Channel is always shipped as 0. There are 10 channels
in the USA and Canada. The Channel for the RF Laser Reader is set
by scanning the Setup Menu.
All Lasers and associated Base Station must be set to the same
channel. If you have more than one RF Laser per Base Station, you
must set a unique ID in each RF Laser. (See SET ID.)
The Laser channel must match the channel on the Base station. See
Appendix A for information on changing the channel on the Base
from the shipped default channel of 0.

Code 3 of 9 (Code 39)

Enable Code 39 0
Disable Code 39 1
Enable Full ASCII Code 39 2
Disable Full ASCII Code 39 3
Enable Code 39 Accumulate Mode 4
Disable Code 39 Accumulate Mode 5
Enable Start/stop character transmission 6
Disable Start/Stop character transmission 7
Enable Mod 43 Check Digit 8
Disable Mod 43 Check Digit 9
Enable Check Digit Transmission A
Disable Check Digit Transmission B
Caps Lock ON C
Caps Lock OFF D
For information about Code 39 and Full ASCII Code 39, see Appendix C.
See page 23 for information about Accumulate Mode (this setting also
controls Code 93 and Code 128).
Enabling Start/Stop character transmission means that the RF Laser Reader
will transmit the * Start/Stop characters to your computer along with the data.
For example, data of 1234 would be transmitted as *1234*.
Enabling the Mod 43 Check Digit requires the units position of your data to
match the calculation for the check digit explained in Appendix C.