Xantrex Technology XW4024-120/240-60 manual Mounting, Mppt Voltage Range, Choosing a Location

Models: XW4548-120/240-60 XW6048-120/240-60 XW4024-120/240-60

1 136
Download 136 pages 15.7 Kb
Page 79
Image 79

Mounting

MPPT Voltage Range

The XW Solar Charge Controller maximum power point tracking algorithm maximizes the output power of PV arrays as long as the operating voltage is within the MPPT operational window. Ensure that the PV array used in the system operates within the MPPT operational window.

Effects of array voltages outside of the MPPT operational window are shown in Table 4-1.

Table 4-1MPPT Operational Window

 

 

 

XW Solar Charge

Voltage

Effect of Array Voltage

Controller Mode

 

 

 

Voc < Battnom

Charge Controller not operating.

Low Light

(system battery voltage)

 

 

VMPP = Battnom to 120 Vdc

Maximum harvest of solar energy.

Charging

 

 

 

(MPPT window)

120 Vdc < VMPP < 140 Vdc

Charge Controller reduces the output

Thermal Derating

 

 

current limit to protect the unit from voltage

 

 

 

spikes.

 

VMPP > 140 Vdc

Charge Controller shuts down. Unit may be

Over-voltage fault.

(or V

> 140 Vdc)

damaged if Voc > 150 V.

 

oc

 

 

Mounting

The instructions in this section apply to an installation including the power distribution panel. Installation procedures will vary according to your specific application. For special applications, consult a qualified electrician or your Xantrex Certified Dealer.

Important: Installations must be compliant with all local electrical codes. Installation of this equipment should only be performed by a qualified electrician or by a Certified Renewable Energy (RE) System installer.

Choosing a Location

The XW Solar Charge Controller is designed to be mounted vertically to the side or the top of the power distribution panel.

The XW Solar Charge Controller must be installed indoors in a dry, protected location away from flammable materials, sources of high temperature, moisture, and vibration, and direct sunlight. The location must also be sheltered from direct sunlight, rain, snow, and wind-blown debris.

CAUTION: Equipment Damage

Never install the XW Solar Charge Controller where it is exposed to salt water spray. Exposure to salt water will void the warranty and may cause a malfunction or a shock hazard.

975-0239-01-01

4–3

Page 79
Image 79
Xantrex Technology XW4024-120/240-60 manual Mounting, Mppt Voltage Range, Choosing a Location, 1MPPT Operational Window